CHAPTER Env-Dw 400 PUBLIC WATER
SYSTEM CLASSIFICATION AND DESIGN
PART
Env-Dw 401 PUBLIC
WATER SYSTEM CLASSIFICATION
Statutory Authority:
RSA 485:1, II(c); RSA 485:3, I; RSA 485:8, I & II
Revision Note:
Document
#10608, effective 6-1-14, adopted Env-Dw 401.01
through Env-Dw 401.03 within a new Part Env-Dw 401 entitled “PWS Classification; Well Siting
Requirements; Hydrogeologic and Engineering Studies” and within a new Chapter
Env-Dw 400 entitled “Public Water System
Classification and Design.” Document
#10608 also readopted with amendments and renumbered former rules Env-Ws 303.04 entitled “Siting Requirements” and Env-Ws 303.06 entitled “Hydrogeologic or Engineering Study”
under a new subtitle as Env-Dw 401.04 and Env-Dw 401.05, respectively.
The redesignation from subtitle Env-Ws to
subtitle Env-Dw was done pursuant to a rules
reorganization plan for Department rules approved by the Director of the Office
of Legislative Services on 9-7-05.
The
former rules Env-Ws 303.03 and Env-Ws 303.06 had last been filed under Document #8498,
effective 11-30-05, which had adopted Env-Ws 303.03
and Env-Ws 303.06.
These rules did not expire on 11-30-13 since they were extended pursuant
to RSA 541-A:14-a until replaced by the rules in Document #10608, effective
6-1-14.
Env-Dw
401.01 Applicability. This chapter applies to public water systems
(PWS)s, as defined in RSA 485:I-a, XV.
Source. #14158, eff 12-25-24
Env-Dw 401.02 Classification
as Community Water System.
(a) The department shall classify a PWS as a
community water system (CWS) if:
(1) The dwellings, units, or other structures
served by the system are suitable for year-round occupancy;
(2) The calculation of the number of year-round
residents does not include weekend, seasonal, or other transient or temporary
occupants; and
(3) Based on (1) and (2) above, the definition of
community water system in RSA 485:1-a, I, is met.
(b) For purposes of (a)(1) above, a dwelling,
unit, or other structure shall be considered suitable for year-round occupancy
if it:
(1) Has insulation, a heating system, a
year-round potable water supply, and indoor plumbing; and
(2) Is served by a wastewater disposal system
that does not discharge untreated waste directly to surface waters and an
alternating current electric power supply.
(c) The department shall classify a PWS as a CWS
if the PWS will ultimately serve a permanent year-round residential population,
even if it initially serves only weekend, seasonal, or other transient or
temporary occupants.
(d) Subject to (e), below, the department shall
determine the population being served by:
(1) For units with 2 or more bedrooms, using an
occupancy of 2.5 people per unit;
(2) For units with less than 2 bedrooms, such as
efficiency apartments, elderly housing units, or other similar types of
residences, using an occupancy of 1.5 people per unit; or
(3) Analyzing an overlay of water system
distribution lines with the most recent U.S. government census estimate using
geographic information system data.
(e) If the PWS owner has existing customer
records that show a different population than is calculated pursuant to (d)
above, the owner may submit the data to the department for purposes of the
department’s calculations.
Source. (See Revision Note at part heading for Env-Dw 401) #10608, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 401.01)
Env-Dw 401.03 Classification
as Non-Community Water System.
(a) The owner
of a CWS may request the department to classify the system as a non-community
water system by submitting the following to the department in writing:
(1) A sworn
affidavit attesting that fewer than 25 people reside at the location for
greater than or equal to 6 months per year;
(2) Flow
records from the system, including from each source which is part of the system
for at least the 2 most recent years; and
(3) One or more
of the following types of documentation to demonstrate that the statement
provided pursuant to (1) above, is true, complete, and not misleading:
a. Voter
registration location for each occupant;
b. Tax records
listing the permanent residence for each occupant;
c. Driver’s
licenses for each occupant; or
d. The lease or
deed restriction, association by-laws, or legal instrument that limits
occupancy by the same people to less than 6 months per year.
(b) The department shall classify a PWS as a
non-community water system if the water system is designed to regularly serve
25 or more people per day for 60 or more days per year but is not a CWS.
(c) The department shall classify a PWS serving a
kindergarten or day care center as a non-transient non-community water system
if the water system serves 25 or more people, including children and staff,
over a 6 month or longer period, as determined by the license issued for such
kindergarten or day care center pursuant to the child care licensing program of
the New Hampshire department of health and human services.
Source. (See Revision Note at part heading for Env-Dw 401) #10608, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 401.02)
Env-Dw 401.04 Availability
of Information; Updates Required.
(a) The owner
shall:
(1) Update the
information submitted pursuant to Env-Dw 401.03(a) as
necessary; and
(2) Make the
information available for review and verification during an inspection of the
water system or upon request by the department.
(b) If the number of year-round residents
changes, the owner shall notify the department as soon as practicable but no
later than 30 days after learning of the change.
Source. (See Revision Note at part heading for Env-Dw 401) #10608, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 401.03)
PART Env-Dw 402 DESIGN STANDARDS FOR ALL PUBLIC WATER SYSTEMS
Revision Note:
Document #10609, effective 6-1-14, readopted with
amendments and renumbered former rules Env-Ws 370.01
through Env-Ws 370.05 in Part Env-Ws
370 , entitled “General Design Standards:
Serving 1,000 or More People”, under a new subtitle as Env-Dw 402.01 through Env-Dw 402.05,
within a new Part Env-Dw 402. The redesignation from subtitle Env-Ws to subtitle Env-Dw was done
pursuant to a rules reorganization plan for Department rules approved by the
Director of the Office of Legislative Services on 9-7-05. Document #10609 also readopted with
amendments and renumbered former rule Env-Ws 344.01,
entitled “Treatment of Contaminants by Flow Mix”, as Env-Dw
402.08.
The former rules Env-Ws
370.01 through Env-Ws 370.05 had last been filed
under Document #8477, effective 11-30-05, and former rule Env-Ws 344.01 had last been filed under Document #8497,
effective 11-30-05. These rules did not
expire on 11-30-13 since they were extended pursuant to RSA 541-A:14-a until
replaced by the rules in Document #10609, effective 6-1-14.
Document
#10609 replaces all prior filings for the former rules Env-Ws
370.01 through Env-Ws 370.05 and Env-Ws 344.01. The prior
filings for former rules Env-Ws 370.01 through Env-Ws 370.05 and Env-Ws 344.01,
beginning as noted below with Document #6521, effective 6-4-97, which had
readopted with amendments the entire Chapter Env-Ws
300, include the following documents:
Env-Ws
370.01-370.03 Env-Ws 370.04 Env-Ws 370.05
#6521, eff 6-4-97 #7105, eff 9-23-99 #7499, eff 5-25-01
#8360, INTERIM, eff 6-4-05 #8477, eff 11-30-05 #8351, eff 5-14-05
#8477, eff 11-30-05 #8477,
eff 11-30-05
Env-Ws
344.01
#6521, eff 6-4-97
#8360, INTERIM, eff 6-4-05
#8497, eff 11-30-05
Env-Dw 402.01 Applicability. The rules of this part shall apply to all
PWSs, as defined in Env-Dw 103.45.
Source. #14158, eff 12-25-24
Env-Dw 402.02 Approvals
Required. No person shall construct,
modify, expand, or enlarge a PWS until all required state and local approvals,
including water system design approval pursuant to this chapter, have been
obtained.
Source. #14158, eff 12-25-24
Env-Dw 402.03 Application
Fee.
(a) As specified in RSA 485:8, III, the applicant
shall pay an application fee for the review of new PWSs or existing PWSs where
conversion from transient use to residential use is proposed.
(b) As required by RSA 485:8, IV, the applicant
shall submit the fee payment at the time of the design review submission.
(c) The amount of the fee shall be based on the
number of residential-type or residential-equivalent units proposed to be
served by the new PWS, determined as follows:
(1) For residential-type units, the fee shall be
as stated in RSA 485:8, III per unit, regardless of the size of the residential
units; and
(2) For non-residential uses, the fee shall be as
stated in RSA 485:8, III per residential-equivalent unit, rounded off to the
nearest full residential-equivalent unit.
(d) A residential-equivalent unit shall be a
design flow of 300 gallons per day (gpd).
(e) The department shall determine the number of
units the system is designed to accommodate based on the applicant’s system
design parameters, proposed plans for additional construction, and other
factors bearing on the ultimate system demand.
(f) Any application for expansion within 2 years
of the initial submittal shall be deemed part of the initial water system
design and therefore subject to the fee.
(g) The maximum fee shall be based on 175
residential units, residential-equivalent units, or a combination of both.
(h) The minimum fee shall be based on 2
residential-equivalent units.
Source. #14158, eff 12-25-24
Env-Dw 402.04 Constructed Conveyances; Distribution
Systems. No constructed conveyance
that is open or that is designed to be open shall be used in any part of any
distribution system that provides drinking water to any member of the public.
Examples of open conveyances that shall be prohibited include but are not
limited to open trenches and aqueducts.
Source. (See Revision Note at part heading for Env-Dw 402) #10609, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 402.05)
Env-Dw 402.05 Treatment of Contaminants by Flow Mix.
(a) For the
purpose of this section, “flow mix” means a treatment technique where the flow
of water from one or more sources having a particular contaminant exceeding an
MCL is combined with flow from one or more different sources having that
contaminant below the MCL, so that the resultant flow is reliably and
consistently below the MCL for that contaminant.
(b) The owner
of a PWS shall use flow mix as a treatment alternative only:
(1) For
contaminants in excess of the MCL specified in Env-Dw
703 through Env-Dw 706; and
(2) In
accordance with this section.
(c) Before
beginning the design of a flow mix treatment system, the owner shall:
(1) Inform the
department that the PWS intends to use the flow mix treatment method; and
(2) Submit to
the department flow mix calculations based on analyses of its water sources
performed within the past 6 years, or a shorter record that demonstrates
consistency of quality, that include the concentration and volume ratios
proposed to be used for each source that demonstrate that the criteria of (d),
below, will be met.
(d) The
department shall approve the use of flow mix if the information submitted
pursuant to (c) above, demonstrates that when the sources are combined at the
correct ratio, the concentration level of the contaminant proposed to be
treated by flow mixing will be reliably and consistently below the applicable
MCL.
(e) The
equipment used to control, verify, and document proper flow mix treatment shall
include:
(1) One control
circuitry for all sources proposed for flow mix;
(2) Flow meters
installed to measure the output from each source to be used;
(3) A rate of
flow controller, either electronic, such as a variable frequency drive, or
mechanical, such as a throttling valve, for each source to allow that source's
output to be regulated;
(4) An
isolation valve for the mixture; and
(5) A sample
tap with a smooth outlet nozzle for each source and for the mixture.
(f) The owner
shall submit, on a quarterly basis:
(1) Records to
document the actual source flows and the calculated, concentration-weighted
ratio of the mixture on a monthly calculation basis; and
(2)
Certification that the established flow mix ratios have been followed.
(g) A water
quality sample shall be taken and analyzed:
(1) From each
source on an annual basis; and
(2) Of the
mixture on a quarterly basis.
Source. (See Revision Note at part heading for Env-Dw 402) #10609, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 402.06)
Env-Dw 402.06 Quality
of Products and Workmanship. The
quality, materials, and workmanship standards of the American Water Works
Association (AWWA), specified in Table 402-1 below and available as noted in
Appendix B, shall apply to all public water systems relative to construction,
operation, and maintenance activities regulated by Env-Dw
300 and Env-Dw 401 through Env-Dw
406.
Table 402-1
Standards of the AWWA
|
STANDARD CATEGORY Subcategory (if any) Number |
Edition |
Title of Standard |
|
SOURCE |
||
|
Groundwater and Wells |
||
|
A100-20 |
2020 |
Water Wells |
|
TREATMENT |
||
|
Filtration |
||
|
B100-16 |
2016 |
Granular Filter Material |
|
B101-22 |
2022 |
Precoat Filter Media |
|
B102-15(R20) |
2015 |
Manganese Greensand for Filters |
|
B112-19 |
2019 |
Microfiltration and Ultrafiltration Membrane Systems |
|
B114-22 |
2022 |
Reverse Osmosis and Nanofiltration Systems for Water
Treatment |
|
B116-19 |
2019 |
Electrodialysis and Ion-Exchange Membrane Systems |
|
B130-23 |
2023 |
Membrane Bioreactor Systems |
|
Softening |
||
|
B200-22 |
2022 |
Sodium Chloride |
|
B201-18 |
2018 |
Soda Ash |
|
B202-19 |
2019 |
Quicklime and Hydrated Lime |
|
Disinfection Chemicals |
||
|
B300-24 |
2024 |
Hypochlorites |
|
B301-24 |
2024 |
Liquid Chlorine |
|
B302-23 |
2023 |
Ammonium Sulfate |
|
B303-18 |
2018 |
Sodium Chlorite |
|
B304-21 |
2021 |
Liquid Oxygen for Ozone Generation for Water,
Wastewater, and Reclaimed Water Systems |
|
B305-22 |
2022 |
Anhydrous Ammonia |
|
B306-22 |
2022 |
Aqua Ammonia (Liquid Ammonium Hydroxide) |
|
Coagulation |
||
|
B402-18 |
2018 |
Ferrous Sulfate |
|
B403-24 |
2024 |
Aluminum Sulfate-Liquid, Ground, or Lump |
|
B404-22 |
2022 |
Liquid Sodium Silicate |
|
B405-24 |
2024 |
Sodium Aluminate |
|
B406-20 |
2020 |
Ferric Sulfate |
|
B407-18 |
2018 |
Liquid Ferric Chloride |
|
B408-18 |
2018 |
Liquid Polyaluminum
Chloride |
|
B451-23 |
2023 |
Poly (Diallyldimethylammonium
Chloride) |
|
B452-20 |
2020 |
EPI-DMA Polyamines |
|
B453-19 |
2019 |
Polyacrylamide |
|
Scale and Corrosion Control |
||
|
B501-19 |
2019 |
Sodium Hydroxide (Caustic Soda) |
|
B502-23 |
2023 |
Sodium Polyphosphate, Glassy (Sodium
Hexametaphosphate) |
|
B503-23 |
2023 |
Sodium Tripolyphosphate |
|
B504-18 |
2018 |
Monosodium Phosphate, Anhydrous and Liquid |
|
B505-18 |
2018 |
Disodium Phosphate, Anhydrous |
|
B506-18 |
2018 |
Zinc Orthophosphate |
|
B507-23 |
2023 |
Phosphoric Acid |
|
B510-18 |
2018 |
Carbon Dioxide |
|
B511-23 |
2023 |
Potassium Hydroxide |
|
B512-23 |
2023 |
Sulfur Dioxide |
|
B550-23 |
2023 |
Calcium Chloride |
|
Taste and Odor Control |
||
|
B600-16 |
2016 |
Powdered Activated Carbon |
|
B601-17 |
2017 |
Sodium Metabisulfite |
|
B602-17 |
2017 |
Copper Sulfate |
|
B603-23 |
2023 |
Permanganates |
|
B604-18 |
2018 |
Granular Activated Carbon |
|
B605-18 |
2018 |
Reactivation of Granulated Activated Carbon |
|
Fluorides |
|
|
|
B701-24 |
2024 |
Sodium Fluoride |
|
B702-24 |
2024 |
Sodium Fluorosilicate |
|
B703-19 |
2019 |
Fluorosilicic Acid |
|
PIPE AND ACCESSORIES |
||
|
Ductile-Iron Pipe and Fittings |
||
|
C104/A21.4-22 |
2022 |
Cement-Mortar Lining for
Ductile-Iron Pipe and Fittings |
|
C105/A21.5-18 |
2018 |
Polyethylene Encasement for
Ductile-Iron Pipe Systems |
|
C110/A21.10-21 |
2021 |
Ductile-Iron and Gray- Iron
Fittings |
|
C111/A21.11-23 |
2023 |
Rubber-Gasket Joints for
Ductile-Iron Pressure Pipe and Fittings |
|
C115/A21.15-20 |
2020 |
Flanged Ductile-Iron PipeWith
Ductile-Iron or Gray-Iron Threaded Flanges |
|
C116/A21.16-22 |
2022 |
Protective Fusion-Bonded Epoxy Coatings for the Interior and Exterior Surfaces of
Ductile-Iron and Gray-Iron Fittings |
|
C150/A21.50-(R23) |
2021 |
Thickness Design of Ductile-Iron Pipe |
|
C151/A21.51-23 |
2023 |
Ductile-Iron Pipe, Centrifugally Cast |
|
C153/A21.53-19 |
2019 |
Ductile-Iron Compact Fittings |
|
Steel Pipe |
||
|
C200-23 |
2023 |
Steel Water Pipe, 6 in. (150 mm) and Larger |
|
C203-20 |
2020 |
Coal-Tar Protective Coatings and Linings for Steel
Water Pipe |
|
C205-18 |
2018 |
Cement-Mortar Protective Lining and Coating for
Steel Water Pipe--4 in. (100 mm) and Larger--Shop Applied |
|
C206-23 |
2023 |
Field Welding of Steel Water Pipe |
|
C207-23 |
2023 |
Steel Pipe Flanges for Waterworks Service,-Sizes 4
in. through 144 in. (100 mm through 3,600 mm) |
|
C208-22 |
2022 |
Dimensions for Fabricated Steel Water Pipe Fittings |
|
C209-19 |
2019 |
Tape Coatings for Steel Water Pipe and Fittings |
|
C210-24 |
2024 |
Liquid-Epoxy Coatings and Linings Steel Water Pipe
and Fittings (C210a-20 Addendum Incorporated) |
|
C213-22 |
2022 |
Fusion-Bonded Epoxy Coatings and Linings for Steel
Water Pipe and Fittings |
|
C214-20 |
2020 |
Machine-Applied Polyolefin Tape Coatings Steel Water
Pipe |
|
C215-22 |
2022 |
Extruded Polyolefin Coatings for Steel Water
Pipelines |
|
C216-22 |
2022 |
Heat-Shrinkable Cross-Linked Polyolefin Coatings for
Steel Water Pipe and Fittings |
|
C217-23 |
2023 |
Microcrystalline Wax and Petrolatum Tape Coatings
Systems for Steel Water Pipe and Fittings |
|
C218-23 |
2023 |
Liquid Coatings for Aboveground Steel Water Pipe and
Fittings |
|
C219-23 |
2023 |
Bolted, Sleeve-Type Couplings for Plain-End Pipe |
|
C220-23 |
2023 |
Stainless-Steel Pipe, ˝ 4 in. (13 mm) and Larger |
|
C221-24 |
2024 |
Fabricated Steel Mechanical Slip-Type Expansion
Joints |
|
C222-18 |
2018 |
Polyurethane Coatings and Linings for Steel Water
Pipe and Fittings |
|
C223-19 |
2019 |
Fabricated Steel and Stainless-Steel Tapping Sleeves |
|
C224-24 |
2024 |
Nylon-11-Based Polyamide Coatings System for the
Interior and Exterior of Steel Water Pipe, Connections, Fittings, and Special
Sections |
|
C225-20 |
2020 |
Fused Polyolefin Coatings Steel Water Pipe |
|
C226-19 |
2019 |
Stainless-Steel Fittings for Waterworks Service,
Sizes ˝ In. Through 72 In. (13 mm Through 1,800 mm) |
|
C227-22 |
2022 |
Bolted, Split-Sleeve Couplings for Plain-End Pipe |
|
C228-19 |
2019 |
Stainless-Steel Pipe Flange Joints for Water Service
– Sizes 2 In. Through 72 In. (50 mm Through 1,800 mm) |
|
C229-20 |
2020 |
Fusion-Bonded Polyethylene Coatings for Steel Water
Pipe and Fittings |
|
C230-22 |
2022 |
Stainless-Steel Full-Encirclement Repair and Service
Connection Clamps for 2-In. Through 12-In. (50-mm Through 300-mm) Pipe |
|
C231-24 |
2024 |
Field Welding of Stainless Steel Water Pipe |
|
C232-22 |
2022 |
Viscoelastic Coatings for Steel Water Pipe and
Fittings |
|
Concrete Pipe |
||
|
C300-22 |
2022 |
Reinforced Concrete Pressure Pipe, Steel-Cylinder
Type |
|
C301-14(R19) |
2014 |
|
|
C302-22 |
2022 |
|
|
C303-24 |
2024 |
Concrete Pressure Pipe, Bar-Wrapped, Steel-Cylinder
Type |
|
C304-14(R19) |
2014 |
Design of Prestressed Concrete Cylinder Pipe |
|
C305-24 |
2024 |
CFRP Renewal and Strengthening of Prestressed
Concrete Cylinder Pipe (PCCP) |
|
Valves and Hydrants |
||
|
C500-19 |
2019 |
Metal-Seated Gate Valves for Water Supply Service |
|
C502-18 |
2018 |
Dry-Barrel Fire Hydrants |
|
C503-21 |
2021 |
Wet-Barrel Fire Hydrants |
|
C504-23 |
2023 |
Rubber-Seated Butterfly Valves |
|
C507-23 |
2023 |
Ball Valves 4 in. through 60 in. (100 mm Through 1,500 mm) |
|
C508-17 |
2017 |
Swing-Check Valves for Waterworks Service, 2 in. Through
24 in. (50 mm through 600 mm) NPS |
|
C509-23 |
2023 |
Resilient-Seated Gate Valves for Water Supply
Service |
|
C510-17(R21) |
2017 |
Double Check Valve Backflow Prevention Assembly |
|
C511-17(R21) |
2017 |
Reduced-Pressure Principle Backflow Prevention
Assembly |
|
C512-15 |
2015 |
Air Release, Air/Vacuum, and Combination Air Valves
for Water and
Wastewater Service |
|
C514-20 |
2020 |
Air Valve and Vent Inflow Preventer Assemblies for Potable Water Distribution System and Storage
Facilities |
|
C515-20 |
2020 |
Reduced-Wall, Resilient-Seated Gate Valves for Water
Supply Service |
|
C516-21 |
2021 |
Large-Diameter Rubber-Seated Butterfly Valves, Sizes
78 In. (2,000 mm) and Larger |
|
C517-16(R21) |
2016 |
Resilient-Seated Cast-Iron Eccentric Plug Valves |
|
C518-18 |
2018 |
Double-Disc Swing-Check Valves for Waterworks
Service, 2 In. Through 48 In. (50 mm Through 1,200 mm) NPS |
|
C519-18 |
2018 |
High-Performance Waterworks Butterfly Valves – 3 In.
(75 mm) Through 60 In. (1,500 mm) |
|
C520-24 |
2024 |
Knife Gate Valves, Sizes 2 In. (50 mm) Through 96
In. (2,400 mm) |
|
C521-23 |
2023 |
Plastic Ball Valves |
|
C522-22 |
2022 |
Rotary Cone Valves, 6 In. Through 60 In. (150 mm
Through 1,500 mm) |
|
C530-22 |
2022 |
Pilot-Operated Control Valves |
|
C541-16(R21) |
2016 |
Hydraulic and Pneumatic Cylinder and Vane-Type
Actuators for Valves and Slide Gates |
|
C542-16(R21) |
2016 |
Electric Motor Actuators for Valves and Slide Gates |
|
C550-17 |
2017 |
Protective Interior Coatings for Valves and Hydrants |
|
C560-21 |
2021 |
Cast-Iron Slide Gates |
|
C561-21 |
2021 |
Fabricated Stainless-Steel Slide Gates |
|
C562-21 |
2021 |
Fabricated Aluminum Slide Gates |
|
C563-21 |
2021 |
Fabricated Composite Slide Gates |
|
PIPE INSTALLATION |
||
|
C600-23 |
2023 |
Installation of Ductile-Iron Water Mains and Their
Appurtenances |
|
C602-23 |
2023 |
Cement-Mortar Lining of Water Pipelines in Place --
4 in. (100 mm) and Larger |
|
C604-17 |
2017 |
Installation of Buried Steel Water Pipe – 4 In. (100
mm) and Larger |
|
C605-21 |
2021 |
Underground Installation of Polyvinyl Chloride (PVC)
and Molecularly Oriented Polyvinyl Chloride (PVCO) Pressure Pipe and Fittings |
|
C606-22 |
2022 |
Grooved and Shouldered Joints |
|
C620-19 |
2019 |
Spray-In-Place Polymeric Lining for Potable Water
Pipelines 4 In. (100 mm) and Larger |
|
C621-18 |
2018 |
Internal Pipe Joint Seal Assemblies for Water
Service |
|
C622-19 |
2019 |
Pipe Bursting of Potable Water Mains 4 In. (100 mm)
to 36 In. (900 mm) |
|
C623-22 |
2022 |
Cured-In-Place Pipe (CIPP) Rehabilitation of
Pressurized Potable Water Pipelines, 4 In. (100 mm) and Larger |
|
DISINFECTION OF FACILITIES |
||
|
C651-23 |
2023 |
Disinfecting Water Mains |
|
C652-19 |
2019 |
Disinfection of Water-Storage Facilities |
|
C653-20 |
2020 |
Disinfection of Water Treatment Plants |
|
C654-21 |
2021 |
Disinfection of Wells |
|
C655-18 |
2018 |
Field Dechlorination |
|
C670-20 |
2020 |
Online Chlorine Analyzer Operation and Maintenance |
|
C671-21 |
2021 |
Online Turbidimeter Operation and Maintenance |
|
METERS |
||
|
C700-20 |
2020 |
Cold-Water Meters – Displacement Type, Bronze Main
Case |
|
C701-19 |
2019 |
Cold-Water Meters – Turbine Type, for Customer
Service |
|
C702-19 |
2019 |
Cold-Water Meters – Compound Type |
|
C703-19 |
2019 |
Cold-Water Meters – Fire-Service Type |
|
C704-19 |
2019 |
Propeller-Type Meters for Waterworks Applications |
|
C707-22 |
2022 |
Encoder-Type Remote-Registration Systems for
Cold-Water Meters |
|
C708-19 |
2019 |
Cold-Water Meters – Multi-jet Type |
|
C710-20 |
2020 |
Cold-Water Meters – Displacement Type, Plastic Main
Case |
|
C712-19 |
2019 |
Cold-Water Meters – Singlejet
Type |
|
C713-19 |
2019 |
Cold-Water Meters – Fluidic-Oscillator Type |
|
C714-19 |
2019 |
Cold-Water Meters for Residential Fire Sprinkler Systems in One- and Two-Family Dwellings and
Manufactured Homes |
|
C715-18(R22) |
2018 |
Cold-Water Meters – Electromagnetic and Ultrasonic
Type, for Revenue Applications |
|
C750-19(R23) |
2019 |
Transit-Time Flowmeters in Full Closed Conduits |
|
C751-19(R23) |
2019 |
Magnetic Inductive Flowmeters |
|
SERVICE LINES |
||
|
C800-21 |
2021 |
Underground Service Line Valves and Fittings |
|
C810-17 |
2017 |
Replacement and Flushing of Lead Service Lines |
|
PLASTIC PIPE |
||
|
C900-22 |
2022 |
Polyvinyl Chloride (PVC) Pressure Pipe and
Fabricated Fittings, 4 in. through 60 in. (100 mm Through 1,500 mm) |
|
C901-20 |
2020 |
Polyethylene (PE) Pressure Pipe and Tubing, ľ in.
(19 mm) through 3 in. (76 mm), for Water Service |
|
C903-21 |
2021 |
Polyethylene-Aluminum-Polyethylene (PE-AL-PE)
Composite Pressure Pipes, 12 mm (1/2 In.) Through 51 mm (2
In.), for Water Service |
|
C904-22 |
2022 |
Crosslinked Polyethylene (PEX) Pressure Tubing, ˝
In. (13 mm) Through 3 In. (76 mm), for Water Service |
|
C906-21 |
2021 |
Polyethylene (PE) Pressure Pipe and Fittings, 4 in.
through 65 in. (100 mm through 1,650 mm), for Waterworks |
|
C907-23 |
2023 |
Injection-Molded Polyvinyl Chloride (PVC) Pressure Fittings, 4 in. through 12 in. (100 mm through 300
mm) for Water, Wastewater, and Reclaimed Water Services. |
|
C909-22 |
2022 |
Molecularly Oriented Polyvinyl Chloride (PVCO)
Pressure Pipe, 4 In.- 24 In. (100 mm-600 mm), for Water,
Wastewater, and Reclaimed Water Service |
|
C950-20 |
2020 |
Fiberglass Pressure Pipe |
|
STORAGE |
||
|
D100-21 |
2021 |
Welded Carbon Steel Tanks for Water Storage |
|
D101-24 |
2024 |
Evaluation of Steel Water Tanks and
Related Facilities |
|
D102-24 |
2024 |
|
|
D103-19 |
2019 |
Factory-Coated Bolted Carbon Steel Tanks for Water
Storage |
|
D104-23 |
2023 |
Automatically Controlled, Impressed-Current Cathodic
Protection for the Interior Submerged Surfaces of Steel Water Storage Tanks |
|
D106-20 |
2020 |
Sacrificial Anode Cathodic Protection Systems for
the Interior Submerged Surfaces of Steel Water Storage Tanks |
|
D107-16 |
2016 |
Composite Elevated Tanks for Water Storage |
|
D108-19 |
2019 |
Aluminum Dome Roofs for Water Storage Facilities |
|
D110-13(R18) |
2013 |
Wire- and Strand-Wound, Circular, Prestressed-
Concrete Water Tanks |
|
D115-20 |
2020 |
Tendon-Prestressed Concrete Water Tanks |
|
D120-19 |
2019 |
Thermosetting Fiberglass-Reinforced Plastic Tanks |
|
D121-12 |
2012 |
Bolted Aboveground Thermosetting
Fiberglass-Reinforced Plastic Panel-Type Tanks for Water Storage |
|
D130-11(R19) |
2011 |
Geomembrane Materials for Potable-Water Storage Applications |
|
PUMPS |
||
|
E102-23 |
2023 |
Submersible Vertical Turbine Pumps |
|
E103-21 |
2021 |
Horizontal Centrifugal and Vertical Line Shaft Pumps |
|
E110-22 |
2022 |
Solids Handling Pumps for Wastewater Applications |
|
E200-23 |
2023 |
Progressive Cavity Chemical Metering Pumps |
|
PLANT EQUIPMENT |
||
|
F101-19 |
2019 |
Contact-Molded, Fiberglass-Reinforced Plastic Wash-
Water Troughs and Launders |
|
F102-19 |
2019 |
Matched-Die-Molded, Fiberglass-Reinforced Plastic
Weir Plates, Scum Baffles, and Mounting Brackets |
|
F110-22 |
2022 |
Ultraviolet Disinfection Systems for Drinking Water |
|
F120-18 |
2018 |
Ozone Systems for Water |
|
F130-22 |
2022 |
Aeration Systems for Biological Wastewater Treatment |
Source. #14158, eff 12-25-24 (formerly
Env-Dw 402.03 and Env-Dw
407.01)
PART
Env-Dw 403 COATINGS,
ADDITIVES, AND LEAD PROHIBITION
Revision Note:
Document
#10610, effective 6-1-14, readopted with amendments and renumbered former Part
Env-Ws 305, entitled “Coatings and Additives; Lead
Prohibition”, under a new subtitle as Part Env-Dw
403, entitled “Coatings, Additives, and Lead Prohibition”. The redesignation from subtitle Env-Ws to subtitle Env-Dw was done
pursuant to a rules reorganization plan for Department rules approved by the
Director of the Office of Legislative Services on 9-7-05.
The
former Part Env-Ws 305 had last been filed under
Document #8498, effective 11-30-05. The
rules in former Part Env-Ws 305 did not expire on
11-30-13 since they were extended pursuant to RSA 541-A:14-a until replaced by
the rules in Document #10610, effective 6-1-14.
Document
#10610 replaces all prior filings for the rules formerly in Env-Ws 305. The prior
filings for rules in the former Env-Ws 305, beginning
with Document #6521, effective 6-4-97, which had readopted with amendments the
entire Chapter Env-Ws 300, include the following
documents:
#6521, eff 6-4-97
#8360, INTERIM, eff 6-4-05
#8498, eff 11-30-05
Env-Dw 403.01 Coatings,
Surfaces, and Additives.
(a) All
chemicals added to drinking water and all coatings and surfaces in contact with
drinking water shall be tested and certified in accordance with the applicable
direct and indirect additives standards “Drinking Water Treatment Chemicals –
Health Effects”, (60) American National Standards Institute (ANSI) document
identification number NSF/ANSI 60-2024, American National Standards Institute,
2024, available as specified in Appendix B, and “Drinking Water System
Components – Health Effects”, (61) ANSI document identification number NSF/ANSI
61-2023, American National Standards Institute, 2023, available as specified in
Appendix B.
(b) For chemicals, the original producer of the
product shall obtain the certification. Repackers of
chemicals shall not be required to obtain separate certification, provided
however, that repackers shall self-certify that the
cleanliness of their procedures and purity of the resultant product is
equivalent to that required of the original manufacturer.
(c) Any person who undertakes reformulation of
chemicals shall obtain certification in accordance with NSF and ANSI 60.
(d) Agencies or firms providing testing and
certification for others shall be certified by NSF and the
ANSI.
Source. (See Revision Note at part heading for Env-Dw 403) #10610, eff 6-1-14; ss by #14158, eff 12-25-24
Env-Dw 403.02 Prohibition
on Use of Lead Pipes, Solder, and Flux.
(a) All pipes, pipe or plumbing fittings or
fixtures, backflow preventers, solder, and flux used in or on drinking water
plumbing shall be lead free as defined in 40 CFR 143.12, 7-1-24 edition.
(b) This section shall not apply to leaded joints
necessary for the repair of cast iron pipes but shall otherwise apply to the
installation or repair of:
(1) Any public
water system; and
(2) Any
plumbing in a residential or non-residential facility providing water for human
consumption which is connected to a public water system.
(c) As provided by the federal Safe Drinking
Water Amendments of 1986 and 40 CFR 143.13 the requirements of (a) above, shall
apply notwithstanding any contrary provision in the state or local plumbing
codes or the rules of the state board for the licensing and regulation of
plumbers.
Source. (See Revision Note at part heading for Env-Dw 403) #10610, eff 6-1-14; ss by #12181, eff 5-23-17; ss
by #14158, eff 12-25-24
Env-Dw 403.03 Distribution
Piping Materials Inventory.
(a) The owner or operator (O/O) of a community
water system (CWS) shall identify and report to the department whether the
following construction materials are present in the distribution system of the
CWS:
(1) Lead from
piping, solder, caulking, interior lining of distribution mains, alloys, and
home plumbing;
(2) Copper from
piping and alloys, service lines, and home plumbing;
(3) Galvanized
piping, service lines, and home plumbing;
(4) Ferrous
piping materials such as cast iron and steel; and
(5) Asbestos
cement pipe.
(b) The O/O shall maintain and update as
necessary a lead service line inventory and lead service line replacement plan
meeting the requirements of 40 CFR 141 Subpart I, 7-1-24 edition.
Source. #12181, eff 5-23-17; ss by #14158, eff
12-25-24
PART Env-Dw 404 DESIGN STANDARDS FOR LARGE COMMUNITY WATER
SYSTEMS AND COMMUNITY WATER SYSTEMS SERVING FIRE PROTECTION HYDRANTS
Revision Note:
Document
#10611, effective 6-1-14, readopted with amendments and renumbered former Part
Env-Ws 374 under a new subtitle as Part Env-Dw 404. The
redesignation from subtitle Env-Ws to subtitle Env-Dw was done pursuant to a rules reorganization plan for
Department rules approved by the Director of the Office of Legislative Services
on 9-7-05.
The
former Part Env-Ws 374 had last been filed under
Document #8478, effective 11-30-05. The
rules in former Part Env-Ws 374 did not expire on
11-30-13 since they were extended pursuant to RSA 541-A:14-a until replaced by
the rules in Document #10611, effective 6-1-14.
Document
#10611 replaces all prior filings for the rules formerly in Env-Ws 374. The prior
filings for rules in the former Env-Ws 374, beginning
with Document #6521, effective 6-4-97, which had readopted with amendments the
entire Chapter Env-Ws 300, include the following
documents:
#6521, eff 6-4-97 (as Env-Ws 375)
#8360, INTERIM, eff 6-4-05 (as Env-Ws 375)
#8478, eff 11-30-05
Env-Dw
404.01 Applicability.
(a) The rules of this part shall apply to CWSs,
as defined in Env-Dw 103.11, that are large community
water systems as defined in Env-Dw 103.27, have fire
protection provided by street hydrants, or use surface water as a source of
water supply.
(b) Requirements for small community water
systems as defined in Env-Dw 103.55 are set forth in
Env-Dw 302, Env-Dw 305, and
Env-Dw 405, as applicable.
(c) For existing large CWSs that propose to
expand or be modified, the design criteria of this part shall apply only to the
component(s) of the CWS affected by the proposed expansion, modification, or
both. For the purposes of this section, “modified” means altered, added to, or
enlarged.
(d) No person shall connect a new or existing
well to a large CWS without prior approval obtained in accordance with Env-Dw 302 and this part.
(e) Any existing water supply source for a large
CWS that has not previously been approved by the department shall meet the
requirements specified in Env-Dw 302.
(f) No person shall start up a large CWS without
obtaining approval for the final design in accordance with Env-Dw 404.03 and without completing the post-construction
procedures required by Env-Dw 404.06.
(g) No person shall connect a large CWS to any
other PWS without obtaining approval for the final design in accordance with
Env-Dw 404.03 and without completing the
post-construction procedures required by Env-Dw
404.06.
(h) Subject
to (i) below, no person shall perform modifications
to an existing large CWS collection, treatment, storage, or distribution
facility, including hydraulic and pumping infrastructure, that could adversely
affect public health, without approval from the department in accordance with
Env-Dw 404.09 below.
(i) Examples of
modifications that could adversely affect public health include, but are not
limited to, addition or replacement of storage tanks, water treatment
facilities, pumping facilities, and distribution piping or addition of service
connections.
(j) Replacement of 500 feet, or less, of piping
with no new service connections or change in pipe size shall not require
approval from the department provided the piping is replaced in accordance with
the design criteria in Env-Dw 404.04 and Env-Dw 404.05.
Source. (See Revision Note at part heading for Env-Dw 404) #10611, eff 6-1-14
New. #14158, eff
12-25-24
Env-Dw
404.02 Application Procedures.
(a) An
applicant requesting approval to construct or register a large CWS pursuant to
this part shall submit the following information to the department
electronically at dwengineering@des.nh.gov:
(1)
An engineer’s report, design drawings, and specifications as specified
in Env-Dw 404.04 and Env-Dw
405.05;
(2)
The well driller’s well completion report for each well as required in
We 800;
(3)
The water quality analysis results of the water from each source as
specified in Env-Dw 302;
(4)
The permitted production volume for each well, approved pursuant to Env-Dw 302;
(5)
If connection to another PWS is proposed, the supplying owner shall
provide information demonstrating:
a.
Adequate quantities of water are available to serve the receiving PWS;
and
b.
With the receiving PWS online, adequate system pressures and source
capacity will be maintained within the supplying PWS;
(6)
The name of a designated primary operator certified in accordance with
Env-Dw 502 or a description of a plan and schedule to
ensure the presence of a certified primary operator upon commencement of
operation of the PWS;
(7)
Business plan pursuant to Env-Dw 602.03;
(8)
Water ordinance or water system rules pursuant to Env-Dw 503.08; and
(9)
An emergency plan pursuant to Env-Dw 503.21.
(b) The applicant shall:
(1)
Ensure that all submitted engineering reports, plans, specifications,
calculations, and other pertinent information relating to the design or
construction of a large CWS are sealed by a professional engineer licensed in
the state of New Hampshire;
(2)
Sign and date the application; and
(3)
Certify that the information provided is accurate.
(c) The design review fee required by Env-Dw 402.03 shall be paid in conjunction with submission of
the application.
(d) An applicant
requesting approval to modify, expand, or enlarge an existing large CWS shall
submit the following to the department electronically at dwengineering@des.nh.gov:
(1)
The name, location, and PWS identifier;
(2)
The name, mailing address, daytime telephone number, and e-mail address
of the contact person who can answer questions about the proposal on behalf of
the owner; and
(3)
The information required in Env-Dw 404.09.
(e) The plans and specifications for all proposed
large CWSs or modifications, including expansions, to existing large CWSs shall
be sealed by a professional engineer licensed in the state of New Hampshire.
Source. (See Revision Note at part heading for Env-Dw 404) #10611, eff 6-1-14
New. #14158, eff 12-25-24
Env-Dw
404.03 Application Approval, Request
for Additional Information, and Denial.
(a) The department shall review the design review
application submitted in accordance with Env-Dw
404.02.
(b) If the department determines that the
application meets the design standards specified in Env-Dw
404.04 and Env-Dw 404.05, the department shall issue
a final design approval and include project-specific conditions as necessary to
ensure compliance with the requirements of these rules and RSA 485.
(c) If the department determines that the
information submitted in the application is insufficient for the department to
determine whether the design standards of Env-Dw
404.04 and Env-Dw 404.05 are met, the department
shall notify the applicant in writing of the additional information needed to
assess the application.
(d) The notice provided by the department
pursuant to paragraph (c) above shall specify:
(1)
What information is needed;
(2)
The deadline for submitting the information, established based on the
type and volume of the information needed but in no case shall be longer than
60 days;
(3)
The provisions of Env-Dw 404.02 relative to
submitting the information; and
(4)
The provisions of paragraphs (e) and (f) below relative to failing to
provide the information.
(e) The department shall deny the application if:
(1)
The applicant does not submit the additional information requested
within the time frame specified in subparagraph (d)(2) above or extended
pursuant to (g) below; or
(2)
The design standards specified in Env-Dw
404.04 and Env-Dw 404.05 are not met.
(f) To request an extension to the deadline
specified in (d)(2) above, the owner shall submit a written request for
extension, including specific reason(s) why the extension is being sought and
the requested revised deadline.
(g) After receiving an extension request, if the
department finds the requirements of (f) above are met, and that an extension
has not previously been granted for this application, the department shall
extend the deadline, for one time only, for 90 days.
(h) Once the department has denied an
application, an applicant wishing to reapply shall submit a new application in
accordance with Env-Dw 404.02 and a new application
fee in accordance with Env-Dw 402.03, as applicable.
Source. (See Revision Note at part heading for Env-Dw 404) #10611, eff 6-1-14
New. #14158, eff 12-25-24
Env-Dw
404.04 Design Standards Adopted by
Reference.
(a) Except as otherwise required by these rules,
collection, treatment, distribution, and storage components and all other
appurtenances of all large CWSs and those CWSs providing fire protection by
means of street hydrants shall be designed in accordance with the practices and
standards set forth in the 2022 edition of “Recommended Standards for Water
Works,” committee report of the Great Lakes - Upper Mississippi River Board of
State and Provincial Public Health and Environmental Managers, available as noted
in Appendix B, with the following exceptions and as further modified by
paragraphs (b) and (c) below and Env- Dw 404.05:
(1)
The foreword; and
(2)
The following sections related to well construction methods:
a. Section
3.2.6.2 (b)(5); and
b. Section
3.2.6.5.
(b) If the local legislative body of a political
subdivision which owns a PWS does not vote to approve funding for the
requirements of the 2022 edition of the "Recommended Standards for Water
Works" as compared to the 1982 edition thereof and the improvements are
not fully funded by the state, the department shall not require the
improvements to be implemented.
(c) The following terms used in the document
adopted by reference at paragraph (a) above, shall be defined, as follows:
(1)
“100-year flood elevation” means the flood hazard elevation determined
in accordance with Env-Dw 404.05(o). This term also includes “highest flood of record”;
(2)
“Subject to flooding” means below the flood hazard elevation;
(3)
“Outside flood plains,” “free from flooding,” and “protected from
flooding” means above the flood hazard elevation; and
(4)
“Flood plain” means the area below the flood hazard elevation.
Source. (See Revision Note at part heading for Env-Dw 404) #10611, eff 6-1-14
New. #14158, eff 12-25-24
Env-Dw
404.05 Additional Design Standards.
(a) In addition to the design criteria specified
in this part, requirements for:
(1)
Surface water filtration, disinfection, and waste recycling shall be as
specified in Env-Dw 716; and
(2)
Source water treatment for corrosion control shall be as specified in
Env-Dw 714.
(b) Site selection, yield and drawdown testing,
and source water protection for wells for large CWSs and water quality for new
wells shall be as specified in Env-Dw 302.
(c) Standards for well abandonment shall be as
specified in We 600 as adopted by the New Hampshire water well board.
(d) Standards for submersible pumps shall be as
specified in We 700 as adopted by the New Hampshire water well board.
(e) Standards for
installation, maintenance, repair, or replacement of well pumps shall be as
specified in We 700 as adopted by the New Hampshire water well board.
(f) The total developed groundwater source
capacity shall equal or exceed the design maximum day demand and equal or
exceed the design average day demand with the largest producing well out of
service.
(g) The source water protection plan for surface
water sources, which may be an existing plan, as described in Part 3.1 of the
document adopted by reference at Env-Dw 404.04(a),
shall:
(1)
Include:
a.
A map showing the delineation of the watershed area contributing water
to the source on an appropriate scale applying standard delineation methods and
identifying smaller priority areas, including riparian buffer zones, priority
sub-watersheds, or both, that present higher vulnerabilities to source water
quality;
b.
A watershed characterization summarizing physical and natural features,
land use, and known waterbody conditions, including pollutant sources and water
quality use impairment(s);
c.
An inventory of known and potential contamination sources, including all
point and non-point pollutant sources having the ability to discharge or
release contaminants to the source or its tributaries within a minimum 6-hour
travel time from the intake;
d.
A determination of susceptibility to contaminant sources that considers,
among other things, the distance, quantity, solubility and toxicity,
dispersion, and dilution of contaminants and review of pertinent compliance
monitoring data reported by a PWS;
e.
A list and description of prioritized and practicable protection actions
having identified milestones to be completed by the owner, committed partners,
or both, which shall include best management practice (BMP) inspections within
a minimum of 4,000-feet upgradient of the intake within the watershed;
f.
A list of recommended protection strategies to be considered by the
owner;
g.
A public education program targeted to watershed residents; and
h.
A schedule with dates for periodic plan updates and evaluation;
(2)
Be approved by the department pursuant to Env-Dw
404.03 prior to placing the proposed surface water source into operation; and
(3)
Be implemented by the owner or partner subsequently identified in the
plan, over a specific timeframe as set forth in the department’s approval
pursuant to (2) above.
(h) Isolation valves shall be located at not more
than 500 foot intervals in areas where the ground elevation is below the flood
hazard elevation as determined in accordance with (o) below and in areas where
water pipes are at a risk of being damaged by erosion.
(i) Run time meters
shall be installed on all pumps.
(j) Water meters shall be:
(1)
Installed to continuously measure the flow from:
a. Each source independently;
b. Any washwater;
c. Any recycled water;
d. Any blended water of different quality;
and
e. The finished water at the distribution
entry point prior to the first customer and after any storage or clearwell at the pumphouse or treatment facility; and
(2)
Maintained in accordance with the standards of the AWWA as required by
Env-Dw 402.
(k) Data from the meters required by (j) above
shall be recorded such that the operator may periodically access and save the
data for tracking purposes. For each source, the monthly volume of withdrawal
and the 24-hour maximum volume for each month shall be recorded and reported to
the department in accordance with Env-Wq 2102.
(l) A sampling point shall be provided after the
last point of chemical injection with consideration given to adequate mixing.
If atmospheric storage is located prior to the first customer, sampling points
shall be provided both upstream and downstream of the atmospheric storage tank
prior to the first customer.
(m) Any PWS that conducts a partial or full
replacement of a lead service line or galvanized service line requiring
replacement shall be subject to the requirements of 40 CFR 141 Subpart I,
7-1-24 edition.
(n) Handling and disposal of lead pipe,
galvanized pipe that might contain lead, or other lead components shall be
subject to Env-Hw 400, Env-Hw
500, Env-Hw 800, and Env-Hw
1200.
(o) In addition to (p) below, the flood hazard
elevation shall be determined using:
(1)
The freeboard value, reached by adding 3 feet to the
1-percent-annual-chance flood elevation, or adding 3 feet to the highest flood
elevation of record, whichever is higher; or
(2)
A best available scientific approach that uses readily available,
actionable hydrologic and hydraulic data and methods that integrate current and
future changes in flooding based on latest climactic predictions.
(p) If the project is for infrastructure within
at least one of New Hampshire’s 17 coastal zone municipalities, including
Dover, Durham, Exeter, Greenland, Hampton, Hampton Falls, Madbury, New Castle,
Newfields, Newington, Newmarket, North Hampton, Portsmouth, Rollinsford, Rye,
Seabrook, and Stratham, determination of the flood hazard elevation specified
in paragraph (o) above shall address projected storm surge, sea level rise, and
precipitation events identified in the “New Hampshire Coastal Flood Risk Summary
– Part I: Science and Part II: Guidance for Using Scientific Projections"
prepared for the New Hampshire Coastal Flood Risk Science and Technical
Advisory Panel 2019 available as noted in Appendix B. A representative
concentration pathway (RCP) of RCP 4.5 or higher and a “low” or “very low”
tolerance for flood risk shall be applied.
(q) If a proposed component of a drinking water
system is proposed to be located below a flood hazard elevation as determined
using the approaches in paragraph (o) above and there are no practicable
alternatives to the proposed site, measures shall be taken to minimize the risk
of flood damage. The designer shall document the mitigating measures or design
modifications that will be taken to reduce the threats from locating the
project below the flood hazard elevation.
(r) No component of a drinking water system shall
be located in a Federal Emergency Management Agency (FEMA)-designated floodway,
with the exception of buried piping.
(s) To the extent practicable, drinking water
facilities shall not be located in areas subject to a risk greater than 1% from
earthquakes, fires, or other disasters that could damage the CWS or a portion
thereof.
Source. (See Revision Note at part heading for Env-Dw 404) #10611, eff 6-1-14
New. #14158, eff 12-25-24
Env-Dw 404.06 PWS Capacity Assurance. A proposed PWS shall meet the requirements of
Env- Dw 602 relative to capacity assurance in order
to receive design approval from the department.
Source. (See Revision Note at part heading for Env-Dw 404) #10611, eff 6-1-14
New. #14158, eff 12-25-24
Env-Dw
404.07 Post-Construction Procedures.
(a) Within 90 days after the water system, or a
portion thereof, is placed into service, record drawings shall be submitted to
the department and to the operator showing precise horizontal dimensional
measurements, depth of bury, material type, and nominal size of all buried
water distribution piping and fittings, and service shut-offs, curb stops,
taps, corporation stops at water mains, and piping, gate valves, blow-offs,
hydrants, flushing devices, and utility crossings.
(b) For purposes of this section, “precise
dimensional measurements” means of sufficient accuracy to locate the piping or
appurtenance to within 1 foot accuracy, recorded to the nearest 0.5 foot.
(c) The owner shall maintain and update, as
necessary, the water system’s record drawings and tie location records based on
the best information available to the owner.
(d) Flushing and chlorination of the water
distribution piping system shall be completed as specified in (e) and (f) below
before use.
(e) Before the inspection of the water system by
the department as required by Env-Dw 404.07, the
entire water system, distribution pipes, storage tanks, and pumps shall be
flushed to remove any dirt or other contaminants, and then chlorinated in
accordance with the appropriate AWWA specification, as specified in Env-Dw 402.
(f) Upon completion of the disinfection, the
system shall then be flushed again until chlorine residual is less than 0.1
milligrams per liter, and a water sample shall be taken from the end of the distribution system and analyzed for
bacterial quality by a laboratory accredited for such test by the New Hampshire
environmental laboratory accreditation program.
(g) The owner shall perform a leakage test of the
piping system before system use. The distribution system shall be checked for
leakage in accordance with the appropriate AWWA standard, as specified in Env-Dw 402. Leakage shall not exceed the value given in the
appropriate AWWA standard.
Source. (See Revision Note at part heading for Env-Dw 404) #10611, eff 6-1-14
New. #14158, eff 12-25-24
Env-Dw
404.08 Notification of Initiation of
Water Service and Request for Inspection.
(a) Subject to (b) below, upon completion of the
construction of a new PWS or modifications to an existing PWS and all required
testing, but no later than 10 days preceding the start of water service, the
owner shall notify the department of the proposed date of the start of water
service and request an inspection of the completed construction. The PWS shall
not initiate service until 10 days after all notifications are provided in
writing to the department.
(b) As part of or prior to the notification
required by paragraph (a) above, the owner shall submit to the department:
(1)
Written verification of completion of construction, disinfection of all
water system components that will come into direct contact with potable water,
and completion of all required testing;
(2)
The operation and maintenance manual required by the document
incorporated by reference at paragraph Env-Dw
404.04(a);
(3)
The record drawings required by Env-Dw
404.06(a); and
(4)
For new PWS, a lead service line inventory and replacement plan meeting
the requirements of 40 CFR 141 Subpart I, 7-1-24 edition.
(c) The certified operator knowledgeable of the
water system shall be in attendance at the inspection by the department.
(d) For existing PWSs, an inspection by the
department shall not be required for construction of water main replacement,
extension, or both, including water service connections, but the owner shall
submit the information required in (b)(1) and (3) above to the department.
Source. (See Revision Note at part heading for Env-Dw 404) #10611, eff 6-1-14
New. #14158, eff 12-25-24
Env-Dw
404.09 Modifications and Expansions.
(a) Any person seeking to expand a large CWS
shall submit the following to the department:
(1)
A water audit conducted in accordance with the standards of the AWWA;
(2)
The proposed increase in average day and maximum day demand due to the
proposed expansion; and
(3)
Documentation demonstrating the existing source(s) have the required
supply capacity as required by Env-Dw 404.04 and Env-Dw 404.05.
(b) Any person seeking to modify or expand a
large CWS in accordance with Env-Dw 404.02 above
shall submit the following to the department:
(1)
A description of the proposed modifications or expansions;
(2)
An explanation of why the modifications or expansions are needed;
(3)
Plan sheets, including revisions to previously approved plans, and
specifications for the proposed modifications or expansion as required by Env-Dw 404.04 and Env-Dw 404.05;
(4)
Revised calculations, as applicable;
(5)
If infrastructure is decommissioned, photo documentation showing a
minimum 12-inch gap in the piping from the original well(s), storage tank(s),
and any other decommissioned infrastructure;
(6)
If connection to another PWS is proposed, documentation from the
supplying owner certifying that:
a.
Adequate quantities of water are available to serve the proposed PWS;
and
b.
With the proposed PWS online, adequate system pressures and source
capacity will be maintained in the supplying PWS; and
(7)
The application fee as required by Env-Dw
402.03.
(c) For deepening or hydrofracturing of wells at
CWSs, the applicant shall comply with Env-Dw 302 and
Env-Dw 305, as applicable.
(d) Replacement in-kind shall not require
department approval, except that replacement of a well shall comply with the
requirements of Env-Dw 302 or Env-Dw
305, as applicable.
(e) The plans and specifications for
modifications to large CWSs shall be sealed by a professional engineer licensed
in the state of New Hampshire.
(f) The department shall approve the application
to modify the CWS if the design meets the criteria in this part.
Source. (See Revision Note at part heading for Env-Dw 404) #10611, eff 6-1-14
New. #14158, eff 12-25-24
Env-Dw
404.10 Expiration and Extension of
Design Approvals.
(a) Any final design approval for large CWS
designs shall expire 4 years after issuance if construction has not been
completed.
(b) A new design review fee and new design
submission including design revision, as applicable, shall be required for
review and re-approval of lapsed designs. The design shall meet the
requirements in effect at the time of the resubmittal.
(c) To request an extension to a large CWS design
approval, the owner shall submit a written request for extension, including:
(1)
Specific reason(s) why the extension is being sought;
(2)
The new construction schedule;
(3)
Confirmation that no changes have been made to the original approved
design; and
(4)
A new water quality test for each source for the applicable parameters
listed in Env-Dw 701 through Env-Dw
706.
(d) After reviewing an extension request, if the
department finds that the previously approved design will ensure that the
project is consistent with all applicable requirements in place at the time the
extension request was received, the department shall extend the approval for a
reasonable amount of time, under the circumstances, not to exceed 4 years.
Source. #14158, eff 12-25-24
Env-Dw
404.11 Waivers.
(a) Any applicant or supplier of water who would
be adversely impacted by the strict application of a rule in this part and who
wishes to request a waiver of the rule shall do so in accordance with Env-Dw 202.
(b) Waivers shall not be granted for requests
that pose a direct risk to public health, including, but not limited to,
improper well construction, solitary wells where multiple wells are required,
failure to comply with water quality standards, or inadequate integrity of the
water storage tank(s).
Source. #14158, eff 12-25-24
PART Env-Dw 405 DESIGN STANDARDS FOR SMALL COMMUNITY WATER
SYSTEMS
Revision Note:
Document
#10612, effective 6-1-14, readopted with amendments and renumbered former Part
Env-Ws 372 under a new subtitle as Part Env-Dw 405. The
redesignation from subtitle Env-Ws to subtitle Env-Dw was done pursuant to a rules reorganization plan for
Department rules approved by the Director of the Office of Legislative Services
on 9-7-05.
The
former Part Env-Ws 372 had last been filed under
Document #8496, effective 11-30-05. The
rules in former Part Env-Ws 372 did not expire on
11-30-13 since they were extended pursuant to RSA 541-A:14-a until replaced by
the rules in Document #10612, effective 6-1-14.
Document
#10612 replaces all prior filings for the rules formerly in Env-Ws 372. The prior
filings for rules in the former Env-Ws 372, beginning
with Document #6521, effective 6-4-97, which had readopted with amendments the
entire Chapter Env-Ws 300, include the following
documents:
#6521, eff 6-4-97
#7105, eff 9-23-99
#8360, INTERIM, eff 6-4-05
#8496, eff 11-30-05
Env-Dw 405.01 Applicability.
(a) The rules of this part shall apply to small
CWSs, as defined in Env-Dw 103.55, including small
CWSs that are being reactivated after being inactive for 6 months for reasons
other than a normal seasonal shutdown.
(b) CWSs, as defined in Env-Dw
103.11, that are large community water systems as defined in Env-Dw 103.27 or have fire protection provided by street
hydrants or use surface water as a source of supply shall meet the requirements
set forth in Env-Dw 302 and Env-Dw
404, as applicable.
(c) Vacation home developments and conversions
from transient use occupancy to year-round residential use shall be considered
CWSs as specified in Env-Dw 401.02(a) through (e).
(d) Water systems designed or intended as CWSs as
specified in Env-Dw 401.02(a) through (e), with fewer
than 15 service connections and fewer than 25 people being served, shall be
subject to the requirements of this part.
(e) For existing small CWSs that propose to
expand or be modified, and those that are ordered by the department to make
water system improvements, the design criteria of this part shall apply only to
the component(s) of the small CWS affected by the proposed expansion,
modification, or both. For the purposes of this part, “modified” means altered,
added to, expanded, or enlarged.
Source. #14158, eff 12-25-24 (formerly Env-Dw 405.02)
Env-Dw 405.02 PWS
Capacity Assurance. A proposed small CWS shall comply with the capacity
requirements of Env-Dw 602 before the operation of
such water system begins.
Source. #14158, eff 12-25-24 (formerly Env-Dw 405.03)
Env-Dw 405.03 Approval Required for New Community Wells
and New Small CWSs.
(a) No person shall connect a new or existing
well to a small CWS without prior approval obtained in accordance with Env-Dw 302 or Env-Dw 305, as
applicable, and this part.
(b) Any existing water supply source for a small
CWS that has not previously been approved by the department shall meet the
requirements specified in Env-Dw 302 or Env-Dw 305, as applicable.
(c) No person shall commence operation of a small
CWS or connect a small CWS to any other PWS without obtaining approval for the
final design in accordance with Env-Dw 405.10 and
without completing the post-construction
procedures required by Env-Dw 405.29.
Source. #14158, eff 12-25-24
Env-Dw 405.04 Approval Required for Modifications
(a) Subject to (c) below, no person shall perform
modifications to an existing small CWS’s collection, treatment, storage, or
distribution facility, including hydraulic and pumping infrastructure, that
could adversely affect public health, without approval from the department in
accordance with Env-Dw 405.31 below.
(b) Examples of modifications that could
adversely affect public health include, but are not limited to, addition or
replacement of storage tanks, water treatment facilities, pumping facilities,
and distribution piping or addition of service connections.
(c) Replacement of 500 feet, or less, of piping
with no new service connections or change in pipe size shall not require
approval from the department provided the piping is replaced in accordance with
Env-Dw 405.27.
Source. #14158, eff 12-25-24
Env-Dw 405.05 Application Procedures.
(a) An applicant requesting approval to construct
or register a new small CWS or reactivate a small CWS shall submit a complete
application, as specified in (b) below, to the department electronically at
dwengineering@des.nh.gov.
(b) An application shall be submitted in 2 parts,
part I, concept approval, and part II, as follows:
(1) Part I
shall be completed as specified in Env-Dw 405.06, and
part II shall be completed as specified in Env-Dw
405.09;
(2) Part I of
the design review application required by Env-Dw
405.06 shall be submitted and approved by the department prior to submission of
the preliminary well report specified in Env-Dw 302
or Env-Dw 305; and
(3) Part II
shall not be submitted until part I has been approved by the department and all
new sources required as part of the design have been approved by the department
in accordance with Env-Dw 302, Env-Dw 305, or both, as applicable.
(c) An applicant requesting approval to modify,
expand, or enlarge an existing small CWS shall submit the following to the
department electronically at dwengineering@des.nh.gov:
(1) The name,
location, and PWS identifier;
(2) The name,
mailing address, daytime telephone number, and e-mail address of the contact
person who can answer questions about the proposal on behalf of the owner; and
(3) The
information required in Env-Dw 405.31.
(d) The plans and specifications for all proposed
small CWSs or modifications, including expansions, to existing small CWSs with
a design flow greater than 20,000 gpd or with 50 or more service connections
shall be sealed by a professional engineer licensed in the state of New
Hampshire.
Source. #14158, eff 12-25-24
Env-Dw 405.06 Application Part I, Concept Approval.
(a) The applicant for a new small CWS shall
provide the following information with part I of the application:
(1) The name,
mailing address, daytime telephone number, and e-mail address of the applicant;
(2) The name
and mailing address of the owner(s) of the property on which the project will
occur, if other than the applicant;
(3) If the
owner or applicant is a corporation, partnership, trust, or any other entity,
the name, mailing address, daytime telephone number, and e-mail address of the
individual representing the owner or applicant;
(4) The name,
mailing address, daytime telephone number, and e-mail address of the consultant
for the project, if any;
(5) The town
tax map(s) and lot number(s) and street address of the property on which the
project is proposed;
(6) A brief
description of the project and whether the proposed small CWS is a phase of a
larger plan of development;
(7) A list of
all existing active and inactive wells or PWSs on the site, their respective
uses, and whether the existing wells will be connected to the proposed CWS or
have been abandoned pursuant to We 404;
(8) A map
specifically locating the proposed service area;
(9) The size of
the proposed PWS, including:
a. The number
of residential units and, for non-domestic flow, the number of residential-
equivalent units based on one residential-equivalent unit being 300 gallons per
day (gpd) design flow and rounding to the nearest full residential-equivalent
unit;
b. The design
flow determined in accordance with Env-Dw 405.11;
c. The required
source capacity calculated pursuant to Env-Dw 405.13;
and
d. For each new
well source proposed, the radius of the sanitary protective area (SPA)
determined in accordance with Env-Dw 405.14;
(10) A vicinity
plan showing nearby existing CWSs;
(11) If a new
well source is proposed, a plan showing a north arrow, plan scale, property
boundaries, tax map and lot numbers of the adjacent lots, a list of abutters,
location of well(s), SPA, buildings, roads, roadway rights-of-way, driveways,
parking areas, snow storage areas, surface waters, wetlands, natural drainage
ways, flood hazard elevation as specified in (b) below, septic tanks, septic
system areas, nitrate setbacks, fuel storage tanks, solid waste disposal areas,
stormwater facilities, and grading; and
(12)
Location(s) and flow(s) of any proposed non-potable well(s); and
(13) If the
application is for a community well approval pursuant to Env-Dw 302 or Env-DW 305, or both as applicable, the
location(s) and flow(s) of any proposed non-potable well(s).
(b) In addition to (c) below, the flood hazard
elevation shall be determined using:
(1) The
freeboard value, reached by adding 3 feet to the one-percent-annual-chance
flood elevation, or adding 3 feet to the highest flood elevation of record,
whichever is higher; or
(2) A best
available scientific approach that uses readily available, actionable
hydrologic and hydraulic data and methods that integrate current and future
changes in flooding based on latest climactic predictions.
(c) If the project is for infrastructure within
at least one of New Hampshire’s 17 coastal zone municipalities, including
Dover, Durham, Exeter, Greenland, Hampton, Hampton Falls, Madbury, New Castle,
Newfields, Newington, Newmarket, North Hampton, Portsmouth, Rollinsford, Rye,
Seabrook, and Stratham, determination of the flood hazard elevation specified
in (b) above, shall address projected storm surge, sea level rise, and
precipitation events identified in the “New Hampshire Coastal Flood Risk
Summary – Part I: Science and Part II: Guidance for Using Scientific
Projections" prepared for the New Hampshire Coastal Flood Risk Science and
Technical Advisory Panel 2019 available as noted in Appendix B. A
representative concentration pathway (RCP) of RCP 4.5 or higher and a “low” or
“very low” tolerance for flood risk shall be applied.
(d) If a new community well is proposed, the
applicant shall comply with the requirements of Env- Dw
302 and Env-Dw 305, as applicable.
(e) If connection to another PWS is proposed, the
supplying PWS owner shall provide information demonstrating:
(1) Adequate
quantities of water are available to serve the proposed PWS; and
(2) With the
proposed PWS online, adequate system pressures and source capacity will be
maintained within the supplying PWS.
Source. #14158, eff 12-25-24
Env-Dw 405.07 Application Approval, Request for
Additional Information, and Denial for Part I – Concept Approval.
(a) The department shall review part I of the
design review application in accordance with Env-Dw
405.08.
(b) If the department determines that the
information submitted in part I of the application meets the criteria specified
in Env-Dw 405.06 and Env-Dw
405.08, the department shall issue a concept approval and include
project-specific conditions as necessary to ensure compliance with the
requirements of these rules and RSA 485.
(c) If the department determines that the
information submitted in part I of the application is insufficient for the
department to determine whether the criteria of Env-Dw
405.06 and Env-Dw 405.08 have been met, the
department shall notify the applicant in writing of the additional information
needed to assess the application.
(d) The notice required by (c) above, shall
specify:
(1) What
information is needed;
(2) The
deadline for submitting the information, established based on the type and
volume of the information needed but in no case shall be longer than 60 days;
(3) The
provisions of Env-Dw 405.06 relative to submitting
the information; and
(4) The
provisions of (e) and (f) below, relative to failing to provide the
information.
(e) If the criteria specified in Env-Dw 405.06 and Env-Dw 405.08 are
still not met, including the information submitted as a result of the notice
made pursuant to (c) above, the department shall notify the applicant a second
time, in accordance with (c) above, in writing of the additional information
needed to assess the application.
(f) The department shall deny the application if
the applicant does not submit the additional information requested within the
time frame specified in (d)(2) above or extended pursuant to (h) below, or the
criteria specified in Env-Dw 405.06 and Env-Dw 405.08 are not met after the second request as specified
in (e) above.
(g) To request an extension to the deadline
specified in (d)(2) above, the owner shall submit a written request for
extension, including specific reason(s) why the extension is being sought and
the requested revised deadline.
(h) After receiving an extension request, if the
department finds the requirements of (g) above are met, and that an extension
has not previously been granted for this application, the department shall
extend the deadline, for one time only, for 90 days.
(i) Once the
department has denied an application, an applicant wishing to reapply shall
submit a new application in accordance with Env-Dw
405.05.
Source. #14158, eff 12-25-24
Env-Dw 405.08 Criteria for Concept Approval for Proposed
Small CWSs.
(a) No well construction or water system design
shall commence on a proposed small CWS until a concept approval is issued by
the department.
(b) The issuance of concept approval for a
proposed small CWS shall be based on the following criteria:
(1) Water
service from another approved PWS is not available, determined based on the
willingness of the potential provider to offer service and a comparison of the
overall project cost to extend water service versus the overall project cost of
constructing the proposed small CWS;
(2) The method
of operation of the proposed small CWS is adequate to ensure that all
applicable requirements of subtitle Env-Dw are met;
(3) The
proposed small CWS is consistent with state, regional, or local water resource
or water supply management plans for the area;
(4) The
proposed small CWS ownership and operation is consistent with other New
Hampshire public utility commission (PUC) franchises in the area;
(5) The
proposed small CWS will use the best feasible source of water available; and
(6) The use of
surface water shall not be allowed as source water for any small CWS. If the
department waives this requirement in accordance with Env-Dw
405.33, the design standards specified in Env-Dw 404
shall apply to the collection and treatment facilities associated with the
surface water source.
(c) For purposes of this section, the best
feasible source of water shall be determined based on a comparison of
alternatives based on project cost and other technical factors. Such a
comparison shall include capital and operational costs to provide an equivalent
level of safe and reliable water supply service from an entity having adequate
financial and managerial capability.
(d) Favorable criteria for the best feasible
source of water concept shall include an interconnection with any of the
following:
(1) Larger
PWSs;
(2) PWSs that
have full time employees who have higher levels of training and experience in
the water works profession;
(3) PWSs with
large volume water storage tank(s); and
(4) PWSs that
have available equipment, controls, and communications that better ensure the
reliability of operations and water quality.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14; ss #14158, eff 12-25-24
(formerly Env-Dw 405.04)
Env-Dw 405.09 Application for Part II, Final Design.
(a) An applicant requiring final design of a
small CWS, including reactivation or registration, shall provide the following
information constituting part II of the application:
(1) A corrected
copy of part I of the application previously submitted, which clearly
identifies any changes from the original submittal, if applicable;
(2) A revised
plan, if different than that submitted with part I of the application pursuant
to Env-Dw 405.06(a);
(3) The well
driller’s well completion report for each well as required in We 800;
(4) The water
quality analysis results of the water from each well as specified in Env-Dw 405.15;
(5) The
permitted production volume of each well proposed to be connected to the small
CWS, approved pursuant to Env-Dw 302, Env-Dw 305, or both as applicable;
(6) The name of
a designated primary operator certified in accordance with Env-Dw 502 or a person that has taken or arranged to take the
operator certification exam as required under Env-Dw
502;
(7) A business
plan pursuant to Env-Dw 602;
(8) A draft
copy of the legal documents related to the creation, ownership, and management
of the proposed CWS;
(9) An
emergency plan pursuant to Env-Dw 503; and
(10) The
following design information, as applicable:
a. For storage
tank(s), the information in Env-Dw 405.16 and Env-Dw 405.21;
b. For booster
pumps, pump controls, and auxiliary equipment, the information in Env-Dw 405.17 and Env-Dw 405.19;
c. For a
pumphouse or pump room, the information in Env-Dw
405.18;
d. For well
appurtenances and pumps, the information in Env-Dw
405.20;
e. For wiring
and controls, the information in Env-Dw 405.22;
f. For water
treatment facilities, the information in Env-Dw
405.23, Env-Dw 405.24, and Env-Dw
405.26; and
g. For water
distribution systems, the information in Env-Dw
405.27.
(b) Any material, product, or equipment
incorporated into a PWS shall comply with the appropriate standard(s) of AWWA,
as specified in Env-Dw 402, if such a standard
exists, and shall be specified in the design information accordingly.
(c) The applicant shall sign and date the
application to certify that the information provided is accurate.
(d) The design review fee required by Env-Dw 402.03 shall be paid in conjunction with submission of
part II of the application.
Source. #14158, eff 12-25-24
Env-Dw 405.10 Application
Approval, Request for Additional Information, and Denial for Part II – Final
Design.
(a) The department shall review part II of the
design review application submitted in accordance with Env-Dw
405.09.
(b) If the department determines that the
information submitted in part II of the application meets the criteria
specified in Env-Dw 405.09 and the design standards
of this part, the department shall issue a final design approval and include
project-specific conditions as necessary to ensure compliance with the
requirements of the rules.
(c) If the department determines that the
information submitted in part II of the application is insufficient for the
department to determine whether the criteria specified in Env-Dw 405.09 or the design standards of this part have been
met, the department shall notify the applicant in writing.
(d) The notice required by (c) above, shall
specify:
(1) What information is needed;
(2) The deadline for submitting the information,
established based on the type and volume of the information needed but in no
case shall be longer than 60 days;
(3) The provisions of Env-Dw
405.09 relative to submitting the information; and
(4) The provisions of Env-Dw
405.10(e) and (f) relative to failing to provide the information.
(e) If the criteria specified in Env-Dw 405.09 are still not met, including the information
submitted as a result of the notice made pursuant to (c) above, the department
shall notify the applicant a second time, in accordance with (c) above, in
writing of the additional information believed by the department to be needed
to assess the application.
(f) The department shall deny the application if
the applicant does not submit the additional information requested within the
time frame specified in (d)(2) above or extended pursuant to (h) below, or the
criteria specified in Env-Dw 405.09 and the design
standards of this part are not met after the second request as specified in (e)
above.
(g) To request an extension to the deadline
specified in (d)(2) above, the owner shall submit a written request for
extension, including specific reason(s) why the extension is being sought and
the requested revised deadline.
(h) After receiving an extension request, if the
department finds the requirements of (g) above are met, and that an extension
has not previously been granted for this application, the department shall
extend the deadline, for one time only, for 90 days.
(i) Once the
department has denied an application, an applicant wishing to reapply shall
submit a new application in accordance with Env-Dw
405.05 and a new application fee in accordance with Env-Dw
405.09(d).
Source. #14158, eff 12-25-24
Env-Dw 405.11 Calculation of the Design Flow.
(a) Subject to (c), below, the design flows for a
CWS shall be the maximum daily water use and shall be determined using one or
more of the following methods:
(1) Using the
values in Table 1008-1 in Env-Wq 1008.03; or
(2) Using
historical water use in accordance with (b) below.
(b) Historical water use shall be determined
using one of the following methods:
(1) If at least
12 months of consecutive daily water meter readings are available, the water
system’s design flow shall be the maximum reported value;
(2) If at least
12 months of consecutive weekly water meter readings are available, the water
system’s design flow shall be the daily average value multiplied by 2; or
(3) If at least
12 months of consecutive monthly water meter readings are available, the water
system’s design flow shall be the daily average value multiplied by 3.
(c)
Since design flows contained in Env-Wq 1008 do not
include exterior water use, for those CWSs where watering lawns and gardens,
filling swimming pools, supplying fire protection systems such as sprinklers,
and other unusually high water demand situations are expected, the design flow
shall be increased accordingly, subject to (d) below.
(d) The CWS shall be designed for all expected
uses. Any uses not accounted for in the design shall be explicitly prohibited
in a legally enforceable document such as condominium bylaws.
Source. #14158, eff 12-25-24
Env-Dw 405.12 Calculation of Peak Flow for CWSs. Peak flow shall be calculated as design flow
times the multiplier in Table 405-1 with the number of residential-equivalent
units being calculated in accordance with Env-Dw
405.06(a)(9)a.:
Table 405-1: Peak Flow
|
Number of
Residential Service Connections or Residential-Equivalent Units |
Peaking Factor
(Peak Flow / Design Flow) |
|
Less than 50 |
10 |
|
50 to 99 |
9 |
|
100 to 149 |
7 |
|
150 to 199 |
5 |
|
Greater than 200 |
4 |
Source. #14158, eff 12-25-24
Env-Dw 405.13 Required Source Capacity.
(a) The total source capacity, including all
sources, for small CWSs shall be not less than 2 times the system’s design flow
based on a 24-hour day.
(b) For small CWSs that are required to have 2 or
more wells, the source capacity with the largest source out of service shall be
not less than 50% of the system’s design flow.
(c) If the design flow exceeds 13,500 gpd, the
CWS shall have a minimum of 2 active wells or an interconnection to another PWS
approved by the department.
(d)
For new wells, the source capacity shall be the permitted production volume
(PPV) approved by the department in accordance with Env-Dw
302 or Env-Dw 305.
(e)
For existing wells with a previously approved PPV, the source capacity shall be
the PPV.
(f)
For existing wells without a previously approved PPV, the source capacity shall
be based on the documentation submitted by the applicant in accordance with
Env-Dw 405.31.
Source. #14158, eff 12-25-24 (formerly Env-Dw 405.12)
Env-Dw 405.14 Determination of the SPA.
(a) The purpose of the SPA shall be to protect
the long-term quality of each PWS well.
(b) The SPA for any
well supplying water to small CWSs shall be established in accordance with Env-Dw 302 or Env-Dw 305, as
applicable.
(c)
Land use within the SPA for small CWSs shall be in accordance with Env-Dw 302, Env-Dw 305, or both as
applicable.
(d) Notwithstanding the requirements of Env-Dw 302 and Env-Dw 305, no well
connected to a PWS shall be located closer to an aboveground storage tank or
underground storage tank than the applicable
distances specified in Env-Or 300 and Env-Or 400, as applicable.
Source. #14158, eff 12-25-24
Env-Dw 405.15 Water Supply Quality Sampling.
(a) Water quality sampling for new, hydrofractured, or deepened community wells shall comply
with Env-Dw 302 or Env-Dw
305, as applicable.
(b) The collection date of the samples taken in
accordance with (a) above, shall be no greater than 6 months prior to the time
the final design application is submitted to the department.
(c) Samples taken in accordance with (a) above,
shall be taken after at least 3 well volumes have been pumped from the well.
(d) The owner shall have the laboratory results
submitted to the department as originals or copies of the originals. Re-typing
or re-writing the data shall not be acceptable.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14; ss #14158, eff 12-25-24
(formerly Env-Dw 405.16
Env-Dw 405.16 Sizing of Storage Tanks.
(a) The required atmospheric water storage
capacity for a small CWS with only one well shall be based on the permitted
production volume (PPV) of the well and the water system’s design flow, as
specified in Table 405-3 below:
Table 405-3: Small CWS That Have Only One Source
|
The water system’s PPV |
Minimum atmospheric water storage capacity required |
|
Greater
than water system’s peak flow |
50
percent of one day’s design flow |
|
Greater
than 2.5 times the design flow |
75
percent of one day’s design flow |
|
Greater
than or equal to 2.0 times the design flow |
100
percent of one day’s design flow |
|
Less
than 2.0 times the design flow |
Not
acceptable |
(b)
The required atmospheric water storage
capacity for a small CWS with more than one well shall be based on the PPVs of
the wells and the water system’s design flow, as specified in Table 405-4
below:
Table 405-4: Requirement for Atmospheric Water
Storage Capacity for Small CWSs That Have More Than One Source
|
The water system’s PPV with the largest producing
well out-of-service |
Minimum atmospheric water storage capacity required |
|
Greater
than water system’s peak flow |
none
required |
|
Greater
than 2.5 times the design flow |
25
percent of one day’s design flow |
|
Greater
than 1.5 times the design flow |
50
percent of one day’s design flow |
|
Greater
than or equal to design flow |
75
percent of one day’s design flow |
|
Less
than design flow |
100
percent of one day’s design flow |
(c) For existing wells without an approved PPV,
the source capacity determined in accordance with Env-Dw
405.13(f) shall be used in place of the PPV in Table 405-3 or Table 405-4, as
applicable, for the purpose of calculating the required atmospheric water
storage capacity.
(d) No atmospheric storage shall be required if
all the following conditions are met:
(1) The
PPV, with the largest producing well
out-of-service, is greater than 2.5 times the design flow;
(2) A step
pumping test run for at least 6 hours demonstrates that the wells can supply
the water system’s peak flow, with the largest producing well out-of-service;
and
(3) The total
pumping capacity of the well pumps, with the largest well pump out of service,
is equal to or greater than the peak flow.
(e) The required hydropneumatic
storage capacity shall be at least 10 percent of design flow, unless the
booster pumps installed per Env-Dw 405.17 are
designed to maintain constant system pressure by using pressure reducing valves
or variable frequency drives.
(f)
To meet the pressure storage requirement of (e) above, pre-charged pressure
storage tanks shall be accepted on an equivalent gross volume basis to
conventional hydropneumatic storage. No more than 6
tanks of the pre-charged pressure type shall be permitted.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14; ss #14158, eff 12-25-24
(formerly Env-Dw 405.18)
Env-Dw 405.17 Sizing, Design, and Installation of Booster
Pumps.
(a) All small CWSs shall comply with this section
relative to booster pumps, which withdraw water from atmospheric storage tanks
and are designed to maintain system pressure by pumping to hydropneumatic
or pressure tanks or by using pressure reducing valves or variable frequency
drives.
(b) Where booster pumps are used, total booster
pump capacity shall be at least equal to peak flow with the largest booster
pump out of service.
(c) Booster pumps shall be connected to a flat,
secure, and durable surface of sufficient strength to withstand vibration,
thrust, and weight. The installed elevation of the pump base shall be at least
8 inches above the finished floor in the pumphouse.
(d) Pumps shall be selected such that they
operate near their best efficiency point during normal operations.
(e) Pump configuration shall account for
anticipated variations in flow rate. Where practicable, multiple pumps, pumps
of different sizes, for example jockey pumps, or both shall be used to optimize
the efficiency of the pumping station electrical use.
(f) All pump motors shall be premium efficiency
motors as defined by the National Electrical Manufacturers’ Association
ANSI/NEMA Standard MG-1-2021, “Motors and Generators”, 2021, available in
Appendix B.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 405.20)
Env-Dw 405.18 Pumphouse Design
and Construction.
(a) For the purpose of this part, “pumphouse”
shall refer to any building or similar structure where components of the water
system are located, including, but not limited to, pumps, electrical system and
controls, treatment equipment, aboveground piping and valves, and
appurtenances. If the building is used for other purposes in addition to water
supply, the room(s) or area(s) of the building where components of the water
system are located shall be considered the pumphouse and shall meet the
requirements of this part.
(b) Pumphouses shall have screened gravity floor
drains or equivalent with all floors pitched Ľ inch per foot toward the drains.
Sump pumps shall not be acceptable in lieu of screened gravity floor drains.
The drain pipes shall not discharge to any surface water and shall be screened
at the discharge end to prevent small animals or insects from blocking flow.
The pumphouse floor level shall be above the seasonal high water table.
(c) The layout of equipment and the design of the
pumphouse shall provide for adequate space to allow operation and preventative
maintenance.
(d) The design and materials shall include
provisions to minimize vandalism damage to wells, doors, and roofs, and shall
not have windows.
(e) The pumphouse walls and ceilings shall be
fully insulated with materials that resist the attraction and residence of
small rodents and similar pests.
(f) Construction materials shall be highly
resistant to moisture, decay, and vandalism.
(g) The owner shall make every reasonable effort
to design and construct the pumphouse at finished grade. For pumphouses that are required to be below
grade due to site constraints, the pumphouse shall be not more than 5 feet
below grade provided that an OSHA-compliant stairway access is provided.
(h) Except as allowed by (i)
below, the floor elevation shall be at or above the flood hazard elevation
determined pursuant to Env-Dw 405.06(b).
(i) If a proposed
component of a drinking water system is proposed to be located below a flood
hazard elevation as determined pursuant to Env-Dw
405.06(b) and there are no practicable alternatives to the proposed site,
measures shall be taken to minimize the risk of flood damage. The designer
shall document the mitigating measures or design modifications that will be
taken to reduce the threats from locating the component below the flood hazard
elevation.
(j) No component of a drinking water system shall
be located in a Federal Emergency Management Agency (FEMA) designated floodway,
with the exception of buried piping.
(k) To the extent practicable, drinking water
facilities shall not be located in areas subject to a risk greater than 1% from
earthquakes, fires, or other disasters that could damage the PWS or a portion
thereof.
(l) A connection for a portable generator,
including receptacle and manual transfer switch, shall be installed to readily
accept portable power generators.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 405.21)
Env-Dw 405.19 Pumps Controls and
Auxiliary Equipment.
(a) In addition to the electrical control system,
an alarm system shall be provided. At a minimum, alarms to note failure of
pumps and low water levels in the atmospheric storage tank(s) shall be
provided. Each alarm shall cause a horn to sound inside the pumphouse and a red
light on the exterior of the pumphouse to be illuminated. Each alarm function
shall be labeled and the alarm shall be equipped with a silencing mechanism.
(b) In instances where the pumphouse is not
easily seen, the alarm system shall include an auto dialer or similar
computerized remote telemetry that will transmit the alarms to the owner or
operator.
(c) Water meters shall be:
(1) Installed
to continuously measure the flow from:
a. Each source
independently;
b. Any washwater;
c. Any recycled
water;
d. Any blended
water of different quality; and
e. The finished
water at the distribution entry point prior to the first customer and after any
storage or clearwell at the pumphouse or treatment
facility; and
(2) Maintained
in accordance with the standards of the AWWA as required by Env-Dw 402.
(d) Data from the meters required under (c) above
shall be recorded such that the operator may periodically access and save the
data for tracking purposes. For each source, the monthly volume of withdrawal
and the 24-hour maximum volume for each month shall be recorded and reported to
the department in accordance with Env-Wq 2102.
(e) A pressure gauge shall be provided on the
discharge line of the well pump prior to the check valve and on the finished
water line entering distribution after storage. Gauges shall be installed with
gauge cocks for isolation and of suitable range for the expected pressure
range.
(f) The water system shall be capable of
receiving an immediate addition of a disinfectant.
(g) Components of the system required by (e)
above, shall include:
(1) An
injection tap on source water feed lines, before all water storage tanks; and
(2) An
electrical outlet interconnected with the source pump electrical system.
(h) All well and booster pump controls shall have
a manual “off/on/automatic” switch to control pump operations.
(i) Air compressors, if needed as part of the system design,
shall be of the oil-less type.
(j) Mercury-type float switches shall be
prohibited and if present shall be removed.
(k) Pump run time meters shall be installed on
all pumps, including, but not limited to, well pumps and booster pumps.
(l) All lubricants for motors, pumps, and other
mechanical equipment that comes into contact with potable water shall be of
food grade oils.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 405.22)
Env-Dw 405.20 Well Appurtenances
and Pump Installation and Design.
(a) No well installed after June 4, 1997 shall be placed inside a pumphouse or building being
served by the water system.
(b) Well casings shall project at least 18 inches
above finished grade and shall terminate at or above the flood hazard elevation
determined pursuant to Env-Dw 405.06(b).
(c) For existing wells vault below finished grade
or other structure where the floor is below finished grade, the well casing
shall extend above the finished floor at least 24 inches and comply with all
construction requirements of We 602.35.
(d) Where existing wells are installed inside a
vault below finished grade or other structure where the floor is below finished
grade, a screened gravity drain line shall be installed that discharges to
daylight and drains during the 100-year flood.
(e) A tight seal shall be provided around all
entry ports into the well, except the well cap shall be vented and screened in
accordance with We 600.
(f) Provisions shall be made to allow the removal
of the well pump for repair.
(g) All well sources shall be capable of being
separately sampled for water quality at a source sample tap. A check valve
shall be located downstream of all source sample taps before entering storage
tank(s), treatment systems, or distribution. Sample taps shall have a smooth
outlet nozzle at least 18 inches above ground and shall be clearly labeled with
the corresponding source ID number.
(h) Wells shall have an appropriately-sized
stilling tube or alternative provisions for electronic drawdown probes
permanently installed in the well so as to allow determination of the static
and drawdown water levels. Existing
wells shall conform with this requirement when the well pump is replaced or
when well pump repair work is next done.
(i) Well pumps shall
be sized to operate during normal operations at or near their best efficiency
point as stated in the manufacturer’s specifications.
(j) All pump motors shall be premium efficiency
motors as defined by ANSI/NEMA Standard MG-1-2021, “Motors and Generators”,
2021, available as noted in Appendix B.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 405.23)
Env-Dw 405.21 Storage Tanks.
(a) All water storage tanks shall have drains.
(b) All water storage tanks shall be located
above the seasonal high water table or fixed to a properly designed
anti-floatation pad or block to prevent possible flotation when empty. Concrete
water storage tanks shall be installed above the seasonal high water table to
protect the contents from possible cross-contamination. Proposals to bury the
concrete water storage tanks into or below the water table shall not be
acceptable.
(c) Atmospheric water storage tanks shall have a
downward turned “U” vent with fine mesh screening and shall be resistant to
vandalism.
(d) To help
ensure the integrity of water storage tanks, all buried steel water storage
tanks shall:
(1) Be
installed in accordance with current industry practice;
(2) Be provided
with an underdrain system to ensure that the seasonal high water table remains
below the bottom of the water storage tank;
(3) Have a
protective interior coating that shall be certified as being manufactured and
applied for use with potable water in accordance with the approved listings in
Env-Dw 403; and
(4) Have a
protective exterior coating, any damage to which shall be repaired prior to
tank backfill.
(e) Atmospheric water storage tanks shall be
equipped with a lockable capped filler pipe to accommodate tank truck water
delivery.
(f) All water storage tanks larger than 500
gallons and installed after January 1, 1996 shall have
a name plate identifying the following:
(1) Year of
manufacture;
(2) Size; and
(3) Pressure
rating.
(g) All pressure tanks shall meet the
requirements of the American Society of Mechanical Engineers (ASME) “Boiler and
Pressure Vessel Code Section VIII-Rules for Construction of Pressure Vessels”,
2023, available as noted in Appendix B, for their intended use.
(h) All new atmospheric storage tanks shall have
a means to access the interior of the tank to facilitate periodic cleaning,
inspection, and the maintenance of interior coatings.
(i) All interior
materials and coatings shall be certified as being manufactured and applied for
use with potable water in accordance with the approved listings in Env-Dw 403.
Source. #14158, eff 12-25-24
Env-Dw 405.22 Wiring and Control
Devices.
(a) All wiring for water system controls and
equipment shall be in accordance with the requirements of the version of the
National Electrical Code used as the basis for licensing electricians in New
Hampshire, as specified in Elec 404.04.
(b) All electrical devices shall be grounded by a
separate and dedicated groundwire.
(c) Convenience outlets shall be of the ground
fault interrupting type.
(d) All junction boxes, relays, and contactors
shall be in enclosures.
(e) All wiring shall be installed in a conduit.
Conduits shall be run no less than 2 feet above the floor. Panels shall be
mounted at least 3.5 feet above the floor unless they are designed and
installed as floor mounted.
(f) All equipment disconnects shall be capable of
being locked out during service.
(g) All relays and starters not part of an
integrated panel shall be labeled.
(h) A detailed schematic of the electrical system
shall be posted in the enclosure or in an obvious place in the pumphouse, and
shall also be part of the operational manual.
(i) All pump controls
shall have a manual “off/on/auto” switch to control pump operations. Where the water is pumped into a pressure
system, a pressure relief valve or similar pressure surge protection shall be
provided with the discharge piped toward a floor drain or exterior drainage.
(j) Mercury-type float switches shall be
prohibited, and shall, if present, be removed and replaced.
(k) The electrical circuits of all chemical feed
pumps shall be interconnected with the electrical circuit of the pump supplying
the water being treated such that the chemical feed pump can only operate when
the water supply pump is pumping. Where water flow requiring the use of a
chemical feed pump varies, the chemical
feed pump speed shall vary automatically proportionally to water flow rate.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 405.25)
Env-Dw 405.23 Treatment Design
Criteria.
(a) When selecting water treatment processes at
small CWSs, the design shall clearly demonstrate consideration of the
following:
(1) Maximizing
the effectiveness of treatment;
(2) Including
sufficient controls and monitors to identify treatment performance and aid in
operation;
(3) Supporting
reliability and flexibility of operations;
(4) Selecting
processes with low capital and operational costs and energy demand;
(5) Designing
equipment to be easily repaired or replaced in-kind to minimize operational
downtime;
(6) Sizing and
configuring equipment consistent with the practices and standards of the
professional water treatment industry; and
(7) Minimizing
waste residuals generation and preventing impacts to the environment.
(b) Where filters are proposed or required,
filter sizing shall minimize head loss and maximize treatment efficiency.
(c) Where filter backwash is required, backwash
controls shall be designed to:
(1) Initiate a
backwash based on volume of water treated, differential pressure, or
contaminant breakthrough and not based on filter run time; and
(2) Minimize
backwash waste volume.
(d) Any non-domestic discharge shall be
registered, permitted, or both as required by local, state, and federal
authorities.
(e) Containers storing treatment chemicals shall
be constructed of materials compatible with the stored chemicals and shall
provide secondary containment for at least 110 percent of the stored volume.
(f) If treatment is proposed or required, the
final design shall:
(1) Describe
the proposed treatment process, including how the process functions
conceptually;
(2) Include a
schematic representation of the treatment process;
(3) Describe
the equipment, chemical(s), plumbing, and electrical control systems that
represent a complete treatment process;
(4) Describe
the anticipated treatment wastes and their disposal, in accordance with Env-Dw 405.24;
(5) Include a
tabular summary of laboratory sampling results analyzed by a New Hampshire-
accredited laboratory, which identifies:
a. The target
contaminant(s) and treatment goals; and
b. All other
water quality parameters, by name and concentration, that might affect or be
affected by the treatment process;
(6) Identify
the configuration of all components of the treatment process, including:
a. The
rationale for a series or parallel configuration;
b. The number
of trains of equipment; and
c. A
description of each pretreatment process;
(7) Identify
the design criteria used for each treatment component of the process,
including:
a. The hydraulic loading rate;
b. The detention time or empty bed contact time;
c. The backwash or regeneration flow rate, and
frequency, volume of discharge, and anticipated contaminant concentrations of
backwash or regeneration events; and
d. The criteria used to establish the need for filter
backwash or media regeneration;
(8) Include a
sampling tap with a smooth outlet nozzle to be installed between each treatment
unit process and identify plumbing appurtenances throughout the treatment
sequence, including:
a. Connecting
pipe size, isolation valves, check valves, unions, and bypasses;
b. Meter(s) and
their type including whether indicating, totalizing, or recording; and
c. Flow
restrictors and their rating;
(9) Identify
measuring, control, and communication or alarm equipment, including:
a. Chemical
feed pump pacing method and associated equipment;
b. Flow switch
interrupt of chemical feed equipment when there is no production flow; and
c. Other
automatic monitoring and communication devices;
(10) For each
treatment chemical to be used:
a. Specify the
chemical feed rate and the target dosage;
b. Provide
documentation demonstrating that the chemical is approved for drinking water
use in accordance with the American National Standards Institute (ANSI)
standard 60 as required in Env-Dw 403; and
c. A copy of
the safety data sheet (SDS) for that chemical; and
(11) Include a
water quality monitoring plan for determining the quality of the treated water
and waste flows, as described in Env-Dw 405.26.
(g) Flow mix, if proposed, shall be in accordance
with Env-Dw 402.04.
(h) A sampling point shall be provided after the
last point of chemical injection with consideration given to adequate mixing.
If atmospheric storage is located prior to the first customer, sampling points
shall be provided both upstream and
downstream of the atmospheric storage tank.
Source. #14158, eff 12-25-24
Env-Dw 405.24 Disposal of
Treatment Wastes and By-Products. The proposal for disposal of treatment wastes
and by-products required by Env-Dw 405.23(f)(4)
shall:
(a) Identify the volume and strength of treatment
wastes and by-products expected to be generated;
(b) Identify whether the expected treatment
wastes or by-products are hazardous and cite the applicable rule(s);
(c) Identify the state agency having jurisdiction
over the treatment wastes or by-products;
(d) Identify the method(s) proposed to dispose of
the treatment wastes or by-products; and
(e) Estimate the annual cost of waste disposal.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 405.28)
Env-Dw 405.25 Operation and
Maintenance Manual.
(a) The owner shall ensure that an operation and
maintenance manual of the water system is on file at the system, and the owner
shall submit said manual to the department.
(b) The manual, electronic or paper, required by
(a) above, shall:
(1) Always be
available on-site at the water system and, if paper, be bound; and
(2) Include the
following:
a. A schematic
drawing of the treatment process, which shall identify each unit of the
treatment equipment by:
1. Type;
2. Size;
3. Model number; and
4. Any appurtenances;
b. An original
or a photocopy of the description of the treatment equipment from the
manufacturer’s catalogue;
c. A separate
schematic drawing of the treatment process in the normal production
configuration, which shall include:
1. A written
description of the process, which shall reference the schematic drawing and
show flow direction; and
2. The
approximate expected values, settings, or feed rates for pumps, gauges, gate
valves, and controllers in the production mode;
d. A separate
schematic drawing of the treatment process in the normal backwash or
regeneration configuration and written description which references the
schematic drawing, showing the backwash or regeneration process functions which
includes:
1. The flow
rate of backwash or regeneration and its temperature dependency where
applicable;
2. The duration
of backwash or regeneration;
3. The
frequency of anticipated backwashes or regenerations;
4. The
approximate expected values, settings, or feed rates for pumps, gauges,
isolation valves, and controllers in the backwash mode; and
5. The backwash
disposal location and a copy of the backwash waste discharge registration
issued by the department;
e. Recommended
short- and long-term maintenance schedules for each piece of equipment;
f. A
description of common operational problems and proposed corrective operator
responses;
g. A
description of how the operator can maximize the efficiency of the treatment
process relative to:
1. Energy use;
2. Chemical
use;
3. Maximizing
the net treated water production volume; and
4. Minimizing
the volume of waste and by-products produced; and
h. A blank copy
of the compliance and oversight operational form that is required by Env-Dw 503 to be submitted to the department when a water
system performs treatment.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 405.29)
Env-Dw 405.26 Water Quality
Monitoring Plan. The water
quality monitoring plan required by Env- Dw
405.23(f)(11) shall:
(a) Identify recommended operational raw water
test parameters and sampling frequencies; and
(b) Identify recommended operational finished
water test parameters and sampling frequencies in addition to compliance
monitoring required in accordance with Env-Dw 701
through Env-Dw 719, as applicable.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 405.30)
Env-Dw 405.27 Distribution System.
(a) Subject to (c) below, the system shall be
designed to maintain a minimum pressure of 20 pounds per square inch (psi) at
ground level at all points in the distribution system under all conditions of
flow. The normal working pressure should be approximately 60 to 80 psi and
shall not be less than 35 psi.
(b) Subject to (c) below, when static pressure
exceeds 100 psi, pressure reducing devices shall be installed on each
individual water service line at the meter or on the water main to maintain
pressure at less than 100 psi. Where pressure reducers are installed below
ground, they shall be located in a vault, which shall have a gravity drain to
daylight with a rodent screen. Any bypass line around a water main pressure
reducer shall also have a pressure reducer. The PWS owner shall maintain all
pressure reducing devices, whether on individual water service lines or on
water mains, in proper working order.
(c) Pressure shall be measured at ground level
including at service connections up to building entrances.
(d) Individual booster pumps shall not be allowed
for any individual residential service from the public water supply mains.
(e) The water distribution piping shall be so
valved as to allow isolation of major sections of the water distribution piping
system for repairs while still providing service to most of the water system.
(f) The spacing for inline isolation valves
installed on water mains shall not exceed every 800 feet. Isolation valves
shall be provided at all intersecting pipes. Isolation valves shall be located
at not more than 500-foot intervals in areas where the ground elevation is
below the flood hazard elevation as determined in accordance with Env-Dw 405.07(b) and in areas where water pipes are at a
reasonable risk of being damaged by erosion.
(g) Blow-offs or similar flushing devices shall
be installed to allow flushing of all water mains in the water distribution
piping system. Flushing devices shall be sized to provide flows which will give
a velocity of at least 3.0 feet per second in the water main being flushed.
Blow-offs and flushing devices shall not have drains, or the drains shall be
plugged, to prevent cross contamination.
(h) Dead-end piping shall be minimized. Dead-end
mains shall be equipped with a means to provide adequate flushing in accordance
with (g) above.
(i) Near the
temporary end of a water main, a gate valve shall be installed to allow future
piping extension without shutting down the system or jeopardizing the health of
existing consumers.
(j) Water distribution piping shall be bedded in
sand or other appropriate material in accordance with the applicable standard
of the AWWA as listed in Env-Dw 402.
(k) Water distribution piping for year-round PWSs
shall be buried below the frost line.
(l) Subject to (n) below, a minimum horizontal
separation of 10 feet shall be maintained between water mains and gravity
sanitary or storm sewers, sewer force mains, sewer manholes, inlets, and other
structures, and septic tanks. The distance shall be measured from outside edge
to outside edge.
(m) Subject to (n) below, if a water main must
cross a gravity sanitary or storm sewer pipe or force main, the water main
shall cross above the sewer pipe with not less than 18 inches of clear
separation. At crossings, one full length of water pipe shall be located so
both joints will be as far from the sewer as possible. Special structural
support for the water and sewer pipes shall be provided as necessary.
(n) When it is impracticable to maintain the
minimum separation distances specified in (l) and (m) above, or when it is
impracticable to install water mains above sanitary or storm sewer pipes,
deviations from the requirements of (l) and (m) above, shall only be allowed if
a specific waiver is granted by the department in accordance with Env-Dw 405.33. In addition to any other condition(s) imposed by
the department in granting the waiver, the following requirements shall apply:
(1) The water
main shall be laid in a separate trench or on an undisturbed earth shelf
located on one side of the sewer and at an elevation so the bottom of the water
main is at least 18 inches above the top of the sewer pipe;
(2) The
sanitary or storm sewer pipe materials shall be pressure rated, and the
manholes, inlets, and other sewer structures shall be watertight and shall be
pressure or leak tested to demonstrate watertightness; and
(3) Where water
piping crosses under sanitary or storm sewer piping, a minimum of 18 inches
clearance shall be required.
(o) The required minimum separation distance
between water pipes and subsurface sewage disposal systems shall be as
specified in Env-Wq 1008.04.
(p)
When pipes cross water bodies 15 feet or wider, pipes shall be buried at least
5 feet below the water body’s bed, and isolation valves shall be installed on
each side of the water body, between the water body and the closest service
connection.
(q) Piping and valving material and installation
techniques shall conform with the appropriate AWWA specification, in accordance
with Env-Dw 402.
(r) Other utilities including but not limited to
natural gas, electric, telephone, steam, and cable television, shall not be
installed within 3 feet of water mains.
(s) All buried non-metallic piping shall be
backfilled with an effective metal tracing element located above the pipe
approximately 6 inches below the finished grade.
(t) Gate valves and house service shut-offs shall
be equipped with cast iron gate box extensions. Gate valve boxes shall have
cast iron covers clearly marked by the word “water” or other appropriate water
supply marking and shall be installed flush with the finished grade.
(u) Rigid connections shall not be used to
construct or repair water distribution piping systems.
(v) The distribution system shall not include any
fixture which incorporates a stop and waste valve cross-connection, unless a
reduced pressure backflow device or air gap is used pursuant to Env-Dw 505.
(w) Any PWS that conducts a partial or full
replacement of a lead service line or galvanized service line requiring replacement is subject to the
requirements of 40 CFR 141 Subpart I, 7-1-24 edition.
(x) Handling and disposal of lead pipe,
galvanized pipe that might contain lead, or other lead components is subject to
Env-Hw 400, Env-Hw 500,
Env-Hw 600, and Env-Hw
1200.
(y) Where it is not practicable to bury a service
line below the frost line all the way to the building entrance, for example
under mobile homes, heat tape shall be installed to prevent the service line
from freezing. The length of above-ground
service pipe shall be minimized.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 405.32)
Env-Dw 405.28 Verification of Quality of Distribution
Pipe Installation.
(a) Water distribution piping at small CWSs shall
be installed in accordance with the provisions of the appropriate AWWA
specification listed in Env-Dw 402, as applicable to
the type of distribution pipe chosen.
(b) At a proposed small CWS, the quality of the
workmanship and adherence to the approved design and pipe specifications shall
be documented in writing to the department in accordance with (c) through (g),
below. Such certification shall not be required for the expansion or
modification of the distribution system once the initial design has been
completed and the water system has been assigned a PWS ID number.
(c) The person who owns and is proposing the
creation of the new small CWS shall retain the services of a qualified third
party who is not an employee and does not otherwise have a financial interest
in the project or legal relationship with the project principals to certify the
quality of the water distribution piping installation.
(d) The following parties shall be acceptable to
the department for providing the certification required by (c) above:
(1) A New
Hampshire-certified water distribution system operator with a grade I or higher
certificate;
(2) A New
Hampshire-licensed civil or sanitary engineer;
(3) A city or
town building or code enforcement official or other person with significant
experience in drinking water industry specifications for piping and pipe
installation of the city or town in which the project is located; or
(4) Another
individual with experience in the construction of PWSs as approved by the
department.
(e) Certification from the owner or developer of
the PWS or from the contractor performing the distribution pipe installation
shall not be acceptable.
(f) The person or firm selected as the third
party to inspect the quality of the distribution piping installation shall:
(1) Inspect a
minimum of 20% of the total footage for each size of water distribution pipe
included on the approved plans; and
(2) Provide to
the department a map identifying the pipe section(s) observed and a certificate
or letter indicating that the quality of the distribution pipe installation met
the applicable AWWA installation standard and was consistent with the best
practices in the industry.
(g) The certificate required by (f)(2) above,
shall include:
(1) The name
and address of the owner or developer;
(2) The name of
the development and city or town in which it is located;
(3) The name of
the street and center line stationing for which the certificate applies;
(4) The name of
the contractor;
(5) Pipe
information including type, size, and cover depth;
(6) The date(s)
of the inspection(s) for the distribution pipe installation;
(7) The
inspector’s qualification pursuant to (d) above, which indicate expertise with
pipe line installation and the applicable AWWA pipe installation standards; and
(8)
Confirmation that the results of the leakage test on the pipe did not
exceed the leakage limits specified in the applicable AWWA pipe installation
standards.
(h) Copies of the leakage test results for the
entire water distribution system and the certificate and map as per (f) above,
shall accompany the as-built plans or record drawings submitted pursuant to
Env-Dw 405.29(b).
(i) Such
certification shall not be required if the total length of new distribution
piping installed is less than 250 feet.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 405.31)
Env-Dw 405.29 Post-Construction
Procedures.
(a) Within 90 days after the water system, or a
portion thereof, is placed into service, record drawings shall be submitted to
the department and to the operator showing precise horizontal dimensional
measurements, depth of bury, material type, and nominal size of all buried
water distribution piping and fittings, and service shut-offs, curb stops,
taps, corporation stops, gate valves, blow-offs, hydrants, flushing devices,
and utility crossings.
(b) For purposes of this section, “precise
dimensional measurements” means of sufficient accuracy to locate the piping or
appurtenance to within 1 foot accuracy, recorded to the nearest 0.5 foot.
(c) Prior to serving water to the public, the
owner shall submit a lead service line inventory and lead service line
replacement plan meeting the requirements of 40 CFR 141 Subpart I to the
department for review and approval.
(d) The owner shall maintain and update, as
necessary, based on the best information available to the owner, the small
CWS’s:
(1) Record
drawings and tie location records as required by Env-Dw
504.08; and
(2) Lead
service line inventory and replacement plan as required by 403.03(b).
(e) Flushing and chlorination of the water
distribution piping system shall be completed before use. Before the inspection
of the water system by the department as required by Env-Dw
405.30, the entire water system, distribution pipes, storage tanks, and pumps
shall be flushed to remove any dirt or other contaminants, and then chlorinated
in accordance with the appropriate AWWA standard, as specified in Env-Dw 402.
(f) Upon completion of the disinfection, the
system shall then be flushed again until chlorine residual is less than 0.1
milligrams per liter, and a water sample shall be taken from the end of the
distribution system and analyzed for bacterial quality by a laboratory
accredited for such test by the New Hampshire environmental laboratory
accreditation program.
(g) The owner shall perform a leakage test of the
piping system before system use. The distribution system shall be checked for
leakage in accordance with the appropriate AWWA standard, as specified in Env-Dw 402. Leakage shall
not exceed the value given in the appropriate AWWA standard.
Source. #14158, eff 12-25-24
Env-Dw 405.30 Notification of
Initiation of Water Service and Request for Inspection.
(a) Subject to (b) below, upon completion of the
construction of a PWS and all required testing, but no later than 10 working
days preceding the start of water service, the owner shall notify the
department of the proposed date of the start of water service and request an
inspection of the water system. The PWS shall not initiate service until 10
days after all notifications are provided in writing to the department
(b) As part of or prior to the notification
required by (a) above, the owner shall submit to the department:
(1) Written
verification of completion of construction, disinfection of all water system
components that will come into direct contact with potable water, and
completion of all required testing;
(2) The
operation and maintenance manual required by Env-Dw
405.25;
(3) The record
drawings required by Env-Dw 405.29(a);
(4) For new
small CWSs, the lead service line inventory and replacement plan as required by
Env-Dw 405.29(c); and
(5) The final
copy of the legal documents pertaining to the creation, ownership, and
management of the proposed CWS.
(c) The certified operator for the water system
shall be in attendance at the inspection by the department.
(d) For existing PWSs, an inspection by the
department shall not be required for construction of water main replacement, or
extension, including water service connections, but the owner shall submit the information required in (b)(1) and (3) above to the
department.
Source. #14158, eff 12-25-24
Env-Dw 405.31 Modifications and
Expansions.
(a) Any person seeking to expand or modify a
small CWS shall submit the following to the department:
(1) Historical
water use data for at least the past 2 years;
(2) The
proposed design flow calculated in accordance with Env-Dw
405.11;
(3)
Documentation demonstrating the existing source(s) have the required
supply capacity as required by Env-Dw 405.13;
(4) A written
request to amend the design approval;
(5) A
description of the necessary changes;
(6) An
explanation of why the changes are needed;
(7) For any new
wells:
a. The well
driller’s well completion report for each well as required in We 800;
b. The water
quality analysis results of the water from each well as specified in Env-Dw 405.15; and
c. The
permitted production volume of each well proposed to be connected to the small
CWS, approved pursuant to Env-Dw 302, Env-Dw 305, or both as applicable;
(8) Plan
sheets, including revisions to previously approved plans, and the following, if
applicable:
a. For storage
tank(s), the information in Env-Dw 405.16 and Env-Dw 405.21;
b. For booster
pumps, pump controls, and auxiliary equipment, the information in Env-Dw 405.17 and Env-Dw 405.19;
c. For a
pumphouse or pump room, the information in Env-Dw
405.18;
d. For well
appurtenances and pumps, the information in Env-Dw
405.20;
e. For wiring
and controls, the information in Env-Dw 405.22;
f. For water
treatment facilities, the information in Env-Dw
405.23, Env-Dw 405.24, and Env-Dw
405.26; and
g. For water
distribution systems, the information in Env-Dw
405.27;
(9) Revised
calculations, as applicable;
(10) If
infrastructure is decommissioned, photo documentation showing a minimum 12-inch
gap in the piping from the original well(s), storage tank(s), and any other
decommissioned infrastructure; and
(11) If
connection to another PWS is proposed, documentation from the supplying owner
certifying that:
a. Adequate
quantities of water are available to serve the proposed PWS;
b. With the
proposed PWS online, adequate system pressures and source capacity will be
maintained; and
c. The design
fee as required by Env-Dw 402.03.
(b) For deepening or hydrofracturing of wells at
CWS, the applicant shall comply with Env-Dw 302 and
Env-Dw 305, as applicable.
(c) Replacement in-kind does not require
department approval, except that replacement of a well shall comply with the
requirements of Env-Dw 302 or Env-Dw
305, as applicable.
(d) The plans and specifications for
modifications to PWSs having a design flow greater than 20,000 gpd shall be
sealed by a professional civil or sanitary engineer licensed in the state of
New Hampshire.
(e) The department shall approve the application
to modify the CWS if the design meets the criteria in this part.
Source. #14158, eff 12-25-24
Env-Dw 405.32 Expiration and
Extension of Design Approvals.
(a) Any final design approval for a proposed
small CWS shall expire 4 years after issuance if the pumphouse and 25% or more
of the proposed water distribution piping system have not been completed and
the water system has not started operation.
(b) A new design review fee and appropriate
design revision shall be required for review and re-approval of lapsed designs.
(c) A new complete water quality test shall be
required for each source for the applicable
parameters
listed in Env-Dw 701 through Env-Dw
706 for re-approval of lapsed designs.
(d) To request an extension to a small CWS design
approval, the owner shall submit a written request for extension, including:
(1) Specific
reason(s) why the extension is being sought;
(2) The new
construction schedule;
(3)
Certification that no changes have been made to the original approved
design; and
(4) A new water
quality test for each source for the applicable parameters listed in Env-Dw 701 through Env-Dw 706.
(e) After
reviewing an extension request, if the department finds that the previously
approved design will ensure that the project is consistent with all applicable
requirements in place at the time the extension request was received, the
department shall extend the approval for a reasonable amount of time, under the
circumstances, not to exceed 4 years.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 405.36)
Env-Dw 405.33 Waivers.
(a) Any applicant or supplier of water who would
be adversely impacted by the strict application of a rule in this part and who wishes to request a waiver
of the rule shall do so in accordance with Env-Dw
202.
(b) Waivers shall not be granted for criteria
which pose a direct risk to public health, such as including, but not limited
to, proper well construction, multiple wells where required, water quality
standards, or the integrity of the water storage tank(s).
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 405.35)
PART
Env-Dw 406 DESIGN STANDARDS FOR NON-COMMUNITY WATER
SYSTEMS
Revision Note:
Document
#10613, effective 6-1-14, readopted with amendments and renumbered former Part
Env-Ws 373 under a new subtitle as Part Env-Dw 406. The
redesignation from subtitle Env-Ws to subtitle Env-Dw was done pursuant to a rules reorganization plan for
Department rules approved by the Director of the Office of Legislative Services
on 9-7-05.
The
former Part Env-Ws 373 had last been filed under
Document #8499, effective 11-30-05, which had adopted Part Env-Ws 373. The rules in
former Part Env-Ws 373 did not expire on 11-30-13
since they were extended pursuant to RSA 541-A:14-a until replaced by the rules
in Document #10613, effective 6-1-14.
Env-Dw 406.01 Applicability.
(a) The rules
of this part shall apply to PWSs that are non-community water systems as
defined by Env-Dw 103.37, which comprise:
(1) Transient
non-community (TNC) water systems, which serve a transitory non-residential
population, such as restaurants, motels, and campgrounds, and serve at least 25
persons in a transitory setting for more than 60 days each year; and
(2)
Non-transient non-community (NTNC) water systems, which serve a regular
but non- residential population such as schools, workplaces, and day care
centers, and serve the same 25 people, or more, over 6 months per year.
(b) Criteria that only apply to a particular type
of non-community water system shall be as noted in each specific rule
requirement.
(c) For existing non-community water systems that
propose to expand or be modified, and those required by the department to make
water system improvements, including new wells, the design criteria of this
part shall apply only to the component(s) of the PWS affected by the proposed
expansion, modification, or both. For the purposes of this part, “modified”
means altered, added to, expanded, or enlarged.
(d) Existing non-community water systems that
have not previously been approved pursuant to this part, shall obtain approval
in accordance with this part.
(e) Non-community water systems that are being
reactivated, if they have been inactive for 6 months or more, shall comply with this part. This shall not include
PWSs that normally open and shut down for seasonal operations.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.02)
Env-Dw 406.02 Public
Water System Capacity Assurance. All
proposed NTNC water systems shall comply with the requirements of Env-Dw 602 before the operation of such water system begins.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.03)
Env-Dw 406.03 Approval Required
for New Non-Community Water Systems.
(a) No person shall connect a new or existing
well that is intended to serve a PWS without prior approval obtained in
accordance with this part.
(b) Any existing water supply source for a PWS
that has not previously been approved by the department shall meet the
requirements specified in this part.
(c) No person shall commence operation of a PWS
or connect to any other PWS without obtaining approval for the final design in
accordance with Env-Dw 406.10 and without completing
the post- construction procedures
required by Env-Dw 406.27.
Source. #14158, eff 12-25-24
Env-Dw 406.04 Approval Required
for Modifications.
(a) Subject to (c) below, no person shall perform
modifications to an existing non-community water system’s collection,
treatment, storage, or distribution facility, including hydraulic and pumping
infrastructure, that could adversely affect public health, without approval
from the department in accordance with Env-Dw 406.29.
(b) Examples of modifications that could
adversely affect public health include, but are not limited to, addition or
replacement of storage tanks, water treatment facilities, pumping facilities,
and distribution piping or addition of service connections.
(c) Replacement of 500 feet, or less, of piping
with no new service connections or change in pipe size shall not require
approval from the department provided the piping is replaced in accordance with
Env-Dw 406.26.
Source. #14158, eff 12-25-24
Env-Dw 406.05 Application
Procedures.
(a) An applicant requesting approval to construct
or register a new PWS or reactivate a PWS shall submit a complete application,
as specified in (b) below, to the department electronically at
dwengineering@des.nh.gov.
(b) An application shall be submitted in two
parts, part I, concept approval, and part II, final design:
(1) Part I
shall be completed as specified in Env-Dw 406.06 and
part II shall be completed as specified in Env-Dw
406.09; and
(2) Part II
shall not be submitted until part I has been approved by the department and all
new sources required as part of the design have been approved by the
department.
(c) An applicant requesting approval to modify,
expand, or enlarge an existing PWS shall submit the following to the department
electronically at dwengineering@des.nh.gov:
(1) The name,
location, and PWS identifier;
(2) The name,
mailing address, daytime telephone number, and e-mail address of the contact
person who can answer questions about the proposal on behalf of the owner; and
(3) The
information required in Env-Dw 406.29.
(d) The plans and specifications for all proposed
non-community water systems or modifications, including expansions, to existing
non-community water systems with a design flow greater than 20,000 gallons per
day (gpd) or with 50 or more service connections shall be stamped by a
professional engineer licensed in the state of New Hampshire.
Source. #14158, eff
12-25-24
Env-Dw 406.06 Application Part I, Concept Approval.
(a) The applicant for a new non-community water
system shall provide the following information with part I of the application:
(1) The name,
mailing address, daytime telephone number, and e-mail address of the applicant;
(2) The name
and mailing address of the owner(s) of the property on which the project will
occur, if other than the applicant;
(3) If the
owner or applicant is a corporation, partnership, trust, or any other entity,
the name, mailing address, daytime telephone number, and e-mail address of the
individual representing the owner or applicant;
(4) The name,
mailing address, daytime telephone number, and e-mail address of the consultant
for the project, if any;
(5) The town
tax map(s) and lot number(s) and street address of the property on which the
project is proposed;
(6) A brief
description of the project and whether the proposed small non-community water
systems is a phase of a larger plan of development;
(7) A list of
all existing active and inactive wells or PWSs on the site, their respective
uses, and whether the existing wells will be connected to the proposed
non-community water systems or have been abandoned pursuant to We 404;
(8) A map
specifically locating the proposed service area;
(9) The size of
the proposed PWS, including:
a. The number
of residential units and, for non-domestic flow, the number of residential-
equivalent units based on one residential-equivalent unit being 300 gpd design
flow and rounding to the nearest full residential-equivalent unit;
b. The design
flow determined in accordance with Env-Dw 406.11;
c. The required
source capacity calculated pursuant to Env-Dw 406.12;
and
d. For each new
well source proposed, the radius of the sanitary protective area (SPA)
determined in accordance with Env-Dw 406.14;
(10) A vicinity
plan showing nearby existing PWSs;
(11) If a new
well source is proposed, a plan covering the extents of the property on which
the well is proposed to be located and the proposed SPA showing a north arrow,
plan scale, property boundaries, tax map and lot numbers of the adjacent lots,
a list of abutters, location of well(s), SPA, buildings, roads, roadway
rights-of-way, driveways, parking areas, snow storage areas, surface waters,
wetlands, natural drainage ways, elevation as specified in (b) below, septic
tanks, septic system areas, nitrate setbacks, fuel storage tanks, solid waste
disposal areas, stormwater facilities, and grading; and
(12)
Location(s) and flow(s) of any proposed non-potable well(s).
(b)
Pursuant to (c) below, the flood hazard elevation shall be determined
using:
(1) The freeboard value, reached by adding 3 feet
to the 1-percent-annual-chance flood elevation, or adding 3 feet to the highest
flood elevation of record, whichever is higher; or
(2) A best
available science approach that uses readily available, actionable hydrologic
and hydraulic data and methods that integrate current and future changes in
flooding based on latest climactic predictions.
(c) If the project is for infrastructure within
at least one of New Hampshire’s 17 coastal zone municipalities, including
Dover, Durham, Exeter, Greenland, Hampton, Hampton Falls, Madbury, New Castle,
Newfields, Newington, Newmarket, North Hampton, Portsmouth, Rollinsford, Rye,
Seabrook, and Stratham, determination of the flood hazard elevation specified
in (b) above shall address projected storm surge, sea level rise, and
precipitation events identified in the “New Hampshire Coastal Flood Risk
Summary – Part I: Science and Part II: Guidance for Using Scientific
Projections" prepared for the New Hampshire Coastal Flood Risk Science and
Technical Advisory Panel 2019 available as noted in Appendix B. A
representative concentration pathway (RCP) of RCP 4.5 or higher and a “low” or
“very low” tolerance for flood risk shall be applied.
(d) If connection to another PWS is proposed, the
supplying owner shall provide information demonstrating:
(1) Adequate
quantities of water are available to serve the proposed PWS; and
(2) With the
proposed PWS online, adequate system pressures and source capacity will be
maintained.
Source. #14158, eff 12-25-24
Env-Dw 406.07 Application
Approval, Request for Additional Information, and Denial for Part I – Concept
Approval.
(a) The department shall review part I of the
design review application in accordance with Env-Dw
406.08.
(b) If the department determines that the
information submitted in part I of the application meets the criteria specified
in Env-Dw 406.06 and Env-Dw
406.08 the department shall issue a concept approval and include
project-specific conditions as necessary to ensure compliance with the
requirements of these rules and RSA 485.
(c) If the department determines that the
information submitted in part I of the application is insufficient for the
department to determine whether the criteria of Env-Dw
406.06 and Env-Dw 406.08 have been met, the
department shall notify the applicant in writing of the additional information
needed to assess the application.
(d) The notice required by (c) above shall
specify:
(1) What
information is needed;
(2) The
deadline for submitting the information, established based on the type and
volume of the information needed but in no case shall be longer than 60 days;
(3) The
provisions of Env-Dw 406.06 relative to submitting
the information; and
(4) The
provisions of (e) and (f) below relative to failing to provide the information.
(e) If the criteria specified in Env-Dw 406.06 and Env-Dw 406.08 are
still not met including the information submitted as a result of the notice
made pursuant to (c) above, the department shall notify the applicant a second
time, in accordance with (c) above, in writing of the additional information
needed to assess the application.
(f) The department shall deny the application if
the applicant does not submit the additional information requested within the
time frame specified in (d)(2) above or extended pursuant to (h) below, or the
criteria specified in Env-Dw 406.06 and Env-Dw 406.08 are not met after the second request as specified
in (e) above.
(g) To request an extension to the deadline
specified in (d)(2) above, the owner shall submit a written request for
extension, including specific reason(s) why the extension is being sought and
the requested revised deadline.
(h) After receiving an extension request, if the
department finds the requirements of (g) above are met, and that an extension
has not previously been granted for this application, the department shall
extend the deadline, for one time only, for 90 days.
(i) Once the
department has denied an application, an applicant wishing to reapply shall
submit a new application in accordance
with Env-Dw 406.06.
Source. #14158, eff 12-25-24
Env-Dw 406.08 Criteria for Concept Approval for a Proposed
Non-Community Water System.
(a) No well construction or water system design
shall commence on a proposed non-community water system until a concept
approval is issued by the department.
(b) The issuance of a concept approval for a
proposed non-community water system shall be based on the following criteria:
(1) Water
service from another approved PWS is not available, determined based on the
willingness of the potential provider to offer service and a comparison of the
overall project cost to extend water service versus the overall project cost of
constructing the proposed non-community water system;
(2) The method
of operation of the proposed non-community water system is adequate to ensure
that all applicable requirements of subtitle Env-Dw
are met;
(3) The
proposed non-community water system is consistent with state, regional, or
local water resource, or water supply management plans for the area;
(4) The
proposed non-community water system ownership and operation is consistent with
other New Hampshire public utility commission (PUC) franchises in the area;
(5) The
proposed non-community water system will use the best feasible source of water
available; and
(6) The use of
surface water shall not be allowed as a source water for any non-community
water system.
(c) For purposes of this section, the best
feasible source of water shall be determined based on a comparison of
alternatives based on project cost and other technical factors. Such a
comparison shall include capital and operational costs to provide an equivalent
level of safe and reliable water supply service from an entity having adequate
financial and managerial capability.
(d) Favorable criteria for the best feasible
source of water concept shall include an interconnection with any of the
following:
(1) Larger
PWSs;
(2) PWSs that
have full time employees who have higher levels of training and experience in
the water works profession;
(3) PWSs with
large volume water storage tank(s); and
(4) PWSs that
have available equipment, controls, and communications that better ensure the
reliability of operations and water quality.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.04)
Env-Dw 406.09 Application for
Part II, Final Design.
(a) An applicant requiring final design of a
non-community water system, including reactivation or registration, shall
provide the following information constituting part II of the application:
(1) A corrected
copy of part I of the application previously submitted, which clearly
identifies any changes from the original submittal, if applicable;
(2) A revised
plan, if different than that submitted with part I of the application pursuant
to Env-Dw 406.06(a);
(3) The well
completion report for each well as required in We 800;
(4) The water
quality analysis results of the water from each well as specified in Env-Dw 406.16;
(5) The well
capacity of each well proposed to be connected to the PWS determined pursuant
to Env-Dw 406.15;
(6) The name of
a designated primary operator certified in accordance with Env-Dw 502 or a person that has taken or arranged to take the
operator certification exam as required under Env-Dw
502;
(7) For NTNC
water systems, a business plan pursuant to Env-Dw
602;
(8) An
emergency plan pursuant to Env-Dw 503;
(9) The
following design information, as applicable:
a. For storage
tank(s), the information in Env-Dw 406.20;
b. For pump
controls and auxiliary equipment, the information in Env-Dw
406.18;
c. For a
pumphouse or pump room, the information in Env-Dw
406.17;
d. For well
appurtenances and pumps, the information in Env-Dw
406.19;
e. For wiring
and control devices, the information in Env-Dw
406.21;
f. For water
treatment facilities, the information in Env-Dw
406.22, Env-Dw 406.23, and Env-Dw
406.25; and
g. For water
distribution systems, the information in Env-Dw
406.26; and
(10) For well
source(s) constituting a large groundwater withdrawal as defined in RSA
485-C:2, a copy of the large groundwater withdrawal permit issued by the
department in accordance with Env-Wq 403.
(b) Any material, product, or equipment
incorporated into a PWS shall comply with the appropriate standard(s) of the
AWWA, as specified in Env-Dw 402 if such a standard
exists, and shall be specified in the design information accordingly.
(c) The applicant shall sign and date the
application to certify that the information provided is accurate.
(d) The design review fee required by Env-Dw 402.03 shall be paid in conjunction with submission of
part II of the application.
Source. #14158, eff 12-25-24
Env-Dw 406.10 Application
Approval, Request for Additional Information, and Denial for Part II – Final
Design.
(a) The department shall review part II of the
design review application submitted in accordance with Env-Dw
406.09.
(b) If the department determines that the
information submitted in part II of the application meets the criteria
specified in Env-Dw 406.09 and the design standards
of this part, the department shall issue a final design approval and include
project-specific conditions as necessary to ensure compliance with the
requirements of the rules.
(c) If the department determines that the
information submitted in part II of the application is insufficient for the
department to determine whether the criteria of Env-Dw
406.09 or the design standards of this part, have been met, the department
shall notify the applicant in writing of the additional information needed to
assess the application.
(d) The notice required by (c) above shall
specify:
(1) What
information is needed;
(2) The
deadline for submitting the information, established based on the type and
volume of the information needed but in no case later than 60 days following
issuance of the notice by the department;
(3) The
provisions of Env-Dw 406.09 relative to submitting
the information; and
(4) The
provisions of (e) and (f) below, relative to failing to provide the
information.
(e) If the criteria specified in Env-Dw 406.09 and the design standards of this part, are still
not met including the information submitted as a result of the notice made
pursuant to (d) above, the department shall notify the applicant a second time,
in accordance with (d) above, in writing of the additional information to be
needed to assess the application.
(f) The department shall deny the application if
the applicant does not submit the additional information requested within the
time frame specified in (d)(2) above or extended pursuant to (h) below, or the
criteria specified in Env-Dw 406.09 and the design
standards of this part are not met after the second request as specified in (e)
above.
(g) To request an extension to the deadline
specified in (d)(2) above, the owner shall submit a written request for
extension, including specific reason(s) why the extension is being sought and
the requested revised deadline.
(h) After receiving an extension request, if the
department finds the requirements of (g) above are met, and that an extension
has not previously been granted for this application, the department shall
extend the deadline, for one time only, for 90 days.
(i) Once the
department has denied an application, an applicant wishing to reapply shall
submit a new application in accordance with Env-Dw
406.05 and a new application fee in accordance with Env-Dw 406.09(d).
Source. #14158, eff 12-25-24
Env-Dw 406.11 Calculation of the
Design Flow.
(a) Subject to (c), below, the design flows for a
non-community water system, shall be the maximum daily water use and shall be
determined using one or more of the following methods:
(1) Using the
values in Table 1008-1 in Env-Wq 1008.03; or
(2) Using
historical water use in accordance with (b) below.
(b) Historical water use shall be determined
using one of the following:
(1) If at least
12 months of consecutive daily water meter readings are available, the water
system’s design flow shall be the maximum reported value;
(2) If at least
12 months of consecutive weekly water meter readings are available, the water
system’s design flow shall be the daily average value multiplied by 2; or
(3) If at least
12 months of consecutive monthly water meter readings are available, the water
system’s design flow shall be the daily average value multiplied by 3.
(c) Since the design flows contained in Env-Wq 1008 do not include exterior water use, for those water
systems where watering lawns and gardens, filling swimming pools, supplying
fire protection systems such as sprinklers, or other high water use demands are
expected, additional supply capacity shall be provided, subject to (d) below.
(d) The PWS shall be designed for all expected
uses. Any uses not accounted for in the design shall be explicitly prohibited.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.08)
Env-Dw 406.12 Required Source Capacity.
(a) The required minimum total source capacity
for non-community water systems shall be not less than 1.5 times the system’s
design flow based on a 24-hour day.
(b) If the design flow exceeds 13,500 gpd, the
PWS shall have a minimum of 2 active wells or an interconnection to another PWS.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.10)
Env-Dw 406.13 Well Location.
(a) Non-community water system wells shall be
located at least 50 feet from the high water line of any surface waters, and 50
feet from any wetlands, and natural drainage ways.
(b) The top of casing of non-community water
system wells shall terminate at or above the flood hazard elevation determined
pursuant to Env-Dw 406.06(b). The owner may add earth
fill adjacent to the well to raise the finished grade around the permanent well
casing for flood protection purposes, provided that all required permits for
placing fill in wetlands and flood plains have been obtained.
(c) Non-community water system wells shall be
located at least 50 feet from the edge of road rights-of-ways, driveways, and
parking areas to reduce contamination from de-icing salts and other
roadway-related potential contamination sources.
(d) No component of a PWS, including wells, shall
be located in a Federal Emergency Management Agency designated floodway, with
the exception of buried piping.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.11)
Env-Dw 406.14 Determination of
the SPA.
(a) The purpose of the SPA shall be to protect
the long-term quality of each PWS well.
(b) The well capacity shall be determined in
accordance with Env-Dw 406.15.
(c) The SPA shall be a circle, centered on the
well, having a radius based on the well capacity as shown in Table 406-1.
Table 406-1: Sanitary Protective Area Radii
|
Well Capacity (gpd) |
Sanitary Protective Radius Length (ft.) |
|
0 – 750 |
75 |
|
751 – 1440 |
100 |
|
1441 – 4320 |
125 |
|
4321 – 14,400 |
150 |
|
14,401 – 28,800 |
175 |
|
28,801 – 57,600 |
200 |
|
57,601 – 86,400 |
250 |
|
86,401 – 115,200 |
300 |
|
115,201 – 144,000 |
350 |
|
Greater than 144,000 |
400 |
(d) When
the SPAs of more than one well overlap, then the individual SPAs for each well
shall be based on their combined well capacity unless the applicant
demonstrates through hydrogeological means that these wells are not
interconnected.
(e) The following land uses shall be specifically
excluded from within the SPAs of non-community water systems:
(1) Wastewater
disposal systems, including septic tanks, grease traps, and effluent disposal
areas;
(2) Soil
fertilization areas;
(3) Nitrate
set-back areas;
(4) Dumpsters;
(5) Detention
ponds or infiltration basins;
(6) Storage
tanks for oil, gasoline, natural gas, diesel fuel, or other hazardous
chemicals; and
(7) Any uses
associated with hazardous materials.
(f) Acceptable uses within the SPA for
non-community water systems shall include those uses listed below:
(1) Roadways, with the exception of the required setback in Env-Dw 406.13(c);
(2) Parking
areas, with the exception of the required setback in
Env-Dw 406.13(c);
(3) Athletic
courts;
(4) Surface
water such as lakes, rivers, and streams, with the exception
of the required setback in Env-Dw 406.13(a);
(5) Permanently
protected or undevelopable land;
(6) Wastewater
piping which passes within the sanitary protective area only if:
a. The type of
pipe is ductile iron or approved equal pressure-type pipe that is tested for
water-tight construction after installation; and
b. All
wastewater piping is located at least 50 feet or a distance equal to one-half
the SPA radius, whichever is greater, from the well;
(7) Pumphouse
and permanent buildings; and
(8) Other
compatible uses proposed in writing to the department by the water system owner
if the submittal demonstrates that:
a. The type(s)
and volume(s) of contaminant(s) associated with the activity, when subject to
any best management practices proposed by the owner,
will not pose a threat to water quality;
b. The owner
has a contaminant mitigation plan that will prevent the contaminant(s) from
rendering the water unfit for use by the PWS; and
c. The overall
risk of groundwater contamination is outweighed by the benefit expected from
the activity.
(g) For non-community water systems, the owner
shall control the SPA. The owner shall, where possible, locate the well and SPA
entirely on the property owned by the PWS. Once
established, the SPA shall not be subdivided. Where the SPA cannot be located
fully on the property owned by the PWS, the owner
shall obtain written legal easements from abutters. Such easements shall
specifically exclude the uses described in (e) above, from the area within the
SPA.
(h) Notwithstanding the requirements of this part
and Env-Dw 302, no well
connected to a PWS shall be located
closer to an aboveground storage tank or underground storage tank than the
applicable distances specified in Env-Or 300 and Env-Or 400, as applicable.
Source. #14158, eff 12-25-24
Env-Dw 406.15 Pumping Tests.
(a) For well source(s) constituting a large
groundwater withdrawal as defined in RSA 485-C:2, the owner shall apply for and
receive a large groundwater withdrawal permit in accordance with Env-Wq 403 prior to submitting part II of the design review
application required by 406.09. Where the requirements of (b) through (h) below
conflict with the requirements of Env-Wq 403, the
stricter requirement shall apply.
(b) For all non-community water systems having a
design flow of 13,500 gpd or greater, the owner shall demonstrate adequate
source capacity by performing a sustained 48-hour pumping test at a constant
rate for all wells proposed to be connected to the PWS. The pumping test shall
meet the requirements of (c) through (h) below and demonstrate stabilized
drawdown for at least the last 12 hours of the test. Stabilization is defined
as a drawdown of less than one inch in 2 hours. If stabilization is not achieved,
the pumping test shall continue and the department shall be contacted.
(c) The owner shall submit data documenting the
pumping test on a pumping test log sheet that includes the following items:
(1) Well depth,
in feet;
(2) The date of
the pumping test;
(3) The pumping
rate, in gallons per minute (gpm);
(4) The level
of water in the well prior to pumping in feet below top of casing;
(5) The
drawdown level during pumping, in feet below top of casing;
(6) The time
the test was initiated and concluded and the total hours of the test;
(7) Water
levels in the PWS’s existing wells as required by (g) and (h) below, where
applicable; and
(8) On-site
weather condition observations during pumping.
(d) Each log
sheet shall be identified by project name, well number or name, location, and
submittal date.
(e) Readings for water level and
pumping rate shall be taken at least every hour so long as the change in
drawdown exceeds 2 feet per hour. Thereafter, readings may be taken at
appropriate intervals not to exceed 4 hours. Readings shall be direct
measurements and not inferred from pump curves or other inferential methods.
(f) Where proposed wells are within 150 feet of
each other, the pumping tests shall be run simultaneously.
(g) For an existing PWS, water levels in the
PWS’s other well(s) shall be recorded before the pumping test starts, during
the pumping test at intervals no greater than once every 4 hours, and just
after the pumping test ends.
(h) For an existing PWS with one or more existing
wells that will continue to be used even if the proposed well is approved, each
other well shall be operated as usual to demonstrate system capacity
requirements as defined in Env-Dw 406.12.
(i) Upon completion
of the pumping test, the department shall determine the well capacity based on
the constant pumping rate at which stabilization is demonstrated.
(j) For all non-community water systems having a
design flow less than 13,500 gpd, the capacity of all wells connected to the PWS shall be determined by either a pumping test
performed pursuant to (b) above or the well completion report submitted by a
licensed well driller in accordance with We 801.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.13)
Env-Dw 406.16 Water Supply Quality Sampling.
(a) The owner shall
take a water sample from each source and have the sample analyzed for quality
by a laboratory accredited by the New Hampshire environmental laboratory
accreditation program for the analysis requested. Results from unaccredited
laboratories shall not be accepted.
(b) Water quality for NTNC water systems shall
meet the applicable standards established in chapter Env-Dw
700 or shall be capable of meeting these
standards with approved treatment.
(c) Wells
proposed to be connected to any non-community water systems shall be sampled
for:
(1) Arsenic;
(2) Total
coliform bacteria and E. coli;
(3) Chloride;
(4) Copper;
(5) Fluoride;
(6) Hardness;
(7) Iron;
(8) Lead;
(9) Manganese;
(10) Nitrate
and nitrite;
(11) pH;
(12) Sodium;
(13) Per- and
Polyfluoroalkyl Substances (PFAS); and
(14) Radon.
(d) In addition to the
sampling required by (c) above, wells proposed to be connected to a NTNC water
system shall be sampled for radionuclides as required by Env-Dw 710.05(c).
(e) The department shall require testing for
additional contaminants if review of available data identifies contamination
sources that might contaminate the well.
(f) The collection date of the samples taken in
accordance with (a) above shall be no greater than 6 months prior to the time
the final design application is submitted to the department.
(g) Samples taken in accordance with (a) above
shall be taken after at least 3 well volumes have been pumped from the well.
(h) The
owner shall have the laboratory results submitted to the department as
originals or copies of the original. Re- typing or re-writing the data shall
not be acceptable.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.14)
Env-Dw 406.17 Pumphouse Design and Construction.
(a) For the purpose of this part,
“pumphouse” shall refer to any building or similar structure where components
of the water system are located, including, but not limited to, pumps,
electrical system and controls, treatment equipment, aboveground piping and
valves, and appurtenances. If the building is used for other purposes in
addition to water supply, the room(s) or area(s) of the building where
components of the water system are located shall be considered the pumphouse
and shall meet the requirements of this part.
(b) Pumphouses shall have screened gravity floor
drains or equivalent with all floors pitched Ľ-inch per foot toward the drains.
Sump pumps shall not be acceptable in lieu of screened gravity floor drains.
The drain pipes shall not discharge to any surface water and shall be screened
at the discharge end to prevent small animals or insects from blocking flow.
(c) The layout of equipment and the design of the
pumphouse shall provide for adequate space to allow operation and preventative
maintenance.
(d) The design and materials shall include
provisions to minimize vandalism damage to wells, doors, and roofs, and shall
not have windows.
(e) The pump station walls and ceilings shall be
fully insulated.
(f) Construction materials shall be highly
resistant to moisture, decay, and vandalism.
(g) The owner shall make every reasonable effort
to design and construct the pumphouse at finished grade. For pumphouses that
are required to be below grade due to site constraints, the pumphouse shall be
not more than 5 feet below grade provided that an OSHA-compliant stairway
access is provided.
(h) Except as allowed by (i)
below, the floor elevation shall be at or above the flood hazard elevation
determined pursuant to Env-Dw 406.06(b).
(i) If a proposed
component of a PWS is proposed to be located below a flood hazard elevation as
determined pursuant to Env-Dw 406.06(b) and there are
no practicable alternatives to the proposed site, measures shall be taken to
minimize the risk of flood damage. The designer shall document the mitigating
measures or design modifications that will be taken to reduce the threats from
locating the component below the flood hazard elevation.
(j) No component of a PWS shall be located in a
Federal Emergency Management Agency (FEMA)-designated floodway, with the
exception of buried piping.
(k) To the extent practicable, drinking water
facilities shall not be located in areas subject to a risk greater than 1% from
earthquakes, fires, or other disasters
that could damage the PWS or a portion thereof.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.16)
Env-Dw 406.18 Pump Controls and Auxiliary Equipment.
(a) A water meter
shall be installed on each incoming source line before the water enters the
storage tank(s).
(b) A pressure gauge shall be provided on the
discharge line of the well pump prior to the check valve and on the finished
water line entering distribution after storage gauges shall be installed with
gauge cocks for isolation and of suitable range for the expected pressure
range.
(c) All well and booster pump controls shall have
a manual “off/on/auto” switch to control pump operations where water is pumped
into a vented tank or the equivalent. Where the water is pumped into a pressure
system, a pressure relief valve or spring-loaded “on” switch shall be provided.
(d) Air compressors, if needed as part of the
system design shall be of the oil-less type.
(e) Mercury-type float switches shall be
prohibited and, if present, shall be removed and replaced.
(f) Pump run time meters shall be installed on
all pumps, including, but not limited to, well pumps and booster pumps.
(g) All lubricants for motors, pumps, and other
mechanical equipment that comes into contact with potable water shall be of
food grade oils.
(h) If the design
flow is equal to or greater than 20,000 gpd, water meters shall be installed to
continuously
measure the flow from each source independently. Said meters shall be
maintained in accordance with the standards of the AWWA as required by Env-Dw 402. Data from said meters shall be recorded such that
the operator can periodically access and save the data for tracking purposes.
For each source, the monthly volume of withdrawal and the 24-hour maximum
volume for each month shall be recorded and reported to the department in
accordance with Env-Wq 2102.
(i) The water system
shall be capable of receiving an immediate addition of a disinfectant.
(j) Components
of the system required by (i) above, shall include:
(1) An
injection tap on source water feed lines, before all water storage tanks; and
(2) An
electrical outlet interconnected with the source pump electrical system.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.17)
Env-Dw 406.19 Well Appurtenances and Pump Installation and Design.
(a) No well installed after June 4, 1997 shall be placed inside a pumphouse or building being
served by the water system.
(b) Well casings shall project at least 18 inches
above finished grade and shall terminate at or above the flood hazard elevation
determined pursuant to Env-Dw 406.06(b).
(c) For existing wells inside a vault below
finished grade or other structure where the floor is below finished grade, the
well casing shall extend above the finished floor at least 2 feet and comply
with all construction requirements of We 602.35.
(d) Where existing wells are installed inside a
vault below finished grade or other structure where the floor is below finished
grade, a screened gravity drain line shall be installed that discharges to
daylight and drains during the 100-year flood.
(e) A tight seal shall be provided around all
entry ports into the well, except the well cap shall be vented and screened in
accordance with the rules of the water well board We 600.
(f) Provisions shall be made to allow the removal
of the well pump for repair.
(g) All well sources at all non-community water
systems shall be capable of being separately sampled for water quality at a
source sample tap. A check valve shall be located downstream of all source
sample taps before entering storage tank(s), treatment systems, or
distribution. Sample taps shall have a smooth nozzle at least 18 inches above
ground and shall be clearly labeled with the corresponding source ID number.
(h) Wells shall have an appropriately-sized
stilling tube or alternative provisions for electronic drawdown probes
permanently installed in the well to allow determination of the static and
drawdown water levels. Existing wells shall conform with this requirement when
the well pump is replaced or when well pump repair work is next done.
(i) Well pumps shall
be sized such that during normal operations they operate at or near their best
efficiency point as stated in the manufacturer’s specifications.
(j) All pump motors shall be premium efficiency
motors as defined by the ANSI/NEMA Standard MG-1-2021, “Motors and Generators”, 2021, available as noted in Appendix B.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.18)
Env-Dw 406.20 Storage Tanks.
(a) All water storage tanks shall have drains.
(b) All water storage tanks shall be located
above the seasonal high ground water table or fixed to a properly designed
anti-floatation pad or block to prevent possible flotation when empty.
(c) Concrete water storage tanks shall be
installed above the seasonal high water table to protect the contents from
possible cross-contamination. Proposals to bury concrete water storage tanks
into or below the water table shall not be accepted.
(d) All atmospheric water storage tanks shall
have a downward-turned "U" vent with fine mesh screening and shall be
resistant to vandalism.
(e) To help ensure
the integrity of water storage tanks, all buried steel water storage tanks
shall:
(1) Be
installed in accordance with current industry practice;
(2) Be provided
with an underdrain system to assure that the seasonal high ground water table
remains below the bottom of the water storage tanks; and
(3) Have a
protective coating inside and out. The interior coating shall be certified as
being manufactured and applied in accordance with the approved listings in Env-Dw 403. Any damage to the exterior coating during
construction shall be repaired prior to tank backfill.
(f) All water
storage tanks larger than 500 gallons and installed after January 1, 1996 shall have a name plate identifying the following:
(1) Year of
manufacture;
(2) Size; and
(3) Pressure
rating.
(g) Atmospheric water
storage tanks shall be equipped with a lockable capped filler pipe to
accommodate tank truck water delivery.
(h) All pressure tanks shall meet the
requirements of the American Society of Mechanical Engineers (ASME) “Boiler and
Pressure Vessel Code Section VIII-Rules for Construction of Pressure Vessels”,
2023 available as noted in Appendix B, for their intended use.
(i) All new
atmospheric storage tanks shall have a means to access the interior of the tank
to facilitate periodic cleaning, inspection, and the maintenance of interior
coatings.
(j) All interior materials and coatings shall be
certified as being manufactured and applied for use with potable water in
accordance with the approved listings in
Env-Dw 403.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.19)
Env-Dw 406.21 Wiring and Control
Devices.
(a) All wiring for
water system controls and equipment shall be in accordance with the
requirements of the version of the National Electrical Code used as the basis
for licensing electricians in New Hampshire, as specified in Elec 404.04. All
wiring shall be installed in conduit.
(b) All electrical devices shall be grounded by a
separate and dedicated groundwire.
(c) Convenience outlets shall be of the ground
fault interrupting type.
(d) All junction boxes, relays, and contactors
shall be in enclosures.
(e) Conduits shall be run no less than 2 feet
above the floor. Panels shall be mounted at least 3.5 feet above the floor
unless they are designed and installed as floor mounted.
(f) All equipment disconnects shall be capable of
being locked out during service.
(g) All relays and starters not part of an
integrated panel shall be labeled.
(h) A detailed schematic of the electrical system
shall be posted in the enclosure or in an obvious place in the pumphouse, and
shall also be part of the operational manual.
(i) All pump controls
shall have a manual “off/on/auto” switch to control pump operations. Where the
water is pumped into a pressure system, a pressure relief valve or similar
pressure surge protection shall be provided with the discharge piped toward a
floor drain or exterior drainage.
(j) Mercury-type float switches are prohibited,
and shall, if present, be removed and replaced.
(k) The electrical circuits of all chemical feed
pumps shall be interconnected with the electrical circuit of the pump supplying
the water being treated such that the chemical feed pump can only operate when
the water supply pump is pumping. Where
water flow requiring the use of a chemical feed pump varies, the chemical feed
pump speed shall vary automatically proportionally to water flow rate.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14
New. #14158, eff 12-25-24
Env-Dw 406.22 Treatment Design
Criteria.
(a) When
selecting water treatment processes at non-community water systems, the
designer shall consider the following:
(1) Maximizing
the effectiveness of treatment;
(2) Including
sufficient controls and monitors to identify treatment performance and aid in
operation;
(3) Supporting
reliability and flexibility of operations;
(4) Selecting
processes with low capital and operational costs and energy demand;
(5) Designing
equipment to be easily repaired or replaced in-kind to minimize operational
downtime;
(6) Sizing and
configuring equipment consistent with the practices and standards of the
professional water treatment industry; and
(7) Minimizing
waste residuals generation and preventing impacts to the environment.
(b) Where filters are
proposed or required, filter sizing shall minimize head loss and maximize
treatment efficiency.
(c) Where
filter backwash is required, backwash controls shall be designed to:
(1) Initiate a
backwash based on volume of water treated, differential pressure, or
contaminant breakthrough and not based on filter run time; and
(2) Minimize
backwash waste volume.
(d) Any non-domestic
discharge shall be registered, permitted, or both as required by local, state,
or federal authorities.
(e) Containers storing treatment chemicals shall
be constructed of materials compatible with the stored chemicals and shall
provide secondary containment for at least 110 percent of the stored volume.
(f) If treatment is proposed or required, the final design shall:
(1) Describe
the proposed water treatment process, including how the process functions
conceptually;
(2) Include a
schematic representation of the treatment process;
(3) Describe
the equipment, chemical(s), plumbing, and electrical and control systems that
represent a complete treatment process;
(4) Describe
the anticipated treatment wastes and their disposal, in accordance with Env-Dw 406.23;
(5) Include a
tabular summary of laboratory sampling results analyzed by a New Hampshire
accredited laboratory which identifies:
a. The
contaminant(s) to be modified by the treatment process; and
b. All other
water quality factors, by name and concentration, that might affect or be
affected by the treatment process;
(6) Identify
the configuration of all components of the treatment process including:
a. The
rationale for a series or parallel configuration;
b. The number
of trains of equipment; and
c. A
description of each pretreatment process;
(7) Describe
the design goal of the treatment process, as follows:
a. Removal of
the contaminant(s) to de minimis levels; or
b. A reduction
of the contaminant so as to achieve compliance with the maximum contaminant
level(s) or the maximum contaminant level goals specified in Env-Dw 702 through Env-Dw 706;
(8) Identify
the design criteria used for each treatment component of the process, as
appropriate, including:
a. The
hydraulic loading rate;
b. The
detention time or empty bed contact time;
c. The backwash
or regeneration flow rate and frequency, volume of discharge, and anticipated
contaminant concentrations of backwash or regeneration events; and
d. The criteria
used to establish the need for filter backwash or media regeneration;
(9) Include a
sampling tap with a smooth outlet nozzle to be installed between each treatment
unit process and identify plumbing appurtenances throughout the treatment
sequence, including:
a. Connecting
pipe size, isolation valves, check valves, unions, and bypasses;
b. Meter(s) and
their type including whether indicating, totalizing or recording; and
c. Flow
restrictors and their rating;
(10) Identify
measuring, control, and communication or alarm equipment including:
a. Chemical
feed pump pacing method and associated equipment;
b. Flow switch
interrupt of chemical feed equipment when there is no production flow; and
c. Other
automatic monitoring and communication devices;
(11) For each
treatment chemical to be used:
a. Specify the
chemical feed rate and target dosage; and
b. Include the
following information:
1.
Documentation that the chemical is approved for drinking water use in
accordance with (ANSI) standard 60 as required in Env-Dw
403; and
2. A copy of
the (SDS) for that chemical; and
(12) Include a
water quality monitoring plan for determining the quality of the treated water
and waste flows, as described in Env-Dw 406.25.
(g) Flow mix, if proposed, shall
be in accordance with Env-Dw 402.04.
(h) A sampling point shall be provided after the
last point of chemical injection. If atmospheric storage is located prior to
the first customer, sampling points shall be provided both upstream and
downstream of the atmospheric storage
tank prior to the first customer.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14
New. #14158, eff 12-25-24
Env-Dw 406.23 Disposal of
Treatment Wastes. The proposal for disposal of treatment wastes and
by-products required by Env-Dw 406.22(f)(4) shall:
(a) Identify the
volume and strength of treatment wastes and by-products expected to be
generated;
(b) Identify whether the expected treatment
wastes or by-products are hazardous and cite the applicable rule(s);
(c) Identify the state agency having jurisdiction
over the treatment wastes or by-products;
(d) Identify the method(s) proposed to dispose of
the treatment wastes or by-products; and
(e) Estimate the annual cost of waste disposal.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.22)
Env-Dw 406.24 Operation and Maintenance Manual.
(a) The owner shall ensure that
an operation and maintenance manual of the water system is on file at the
system, and the owner shall submit said manual to the department as part of or
prior to the notification required by Env-Dw
406.28(a).
(b) The
manual, electronic or paper, required by (a) above, shall:
(1) Always be
available on-site at the water system and, if paper, be bound; and
(2) Include the
following:
a. A schematic
drawing of the treatment process, which shall identify each unit of the
treatment equipment by:
1. Type;
2. Size;
3. Model number; and
4. Any appurtenances;
b. An original
or a photocopy of the description of the treatment equipment from the
manufacturer’s catalogue;
c. A separate
schematic drawing of the treatment process in the normal production
configuration, which shall include:
1. A written description of the process, which shall
reference the schematic drawing and show flow direction; and
2. The approximate expected values, settings, or feed
rates for pumps, gauges, gate valves, and controllers in the production mode;
d. A separate
schematic drawing of the treatment process in the normal backwash or
regeneration configuration, which shall include:
1. A written description which references the
schematic drawing, showing the backwash or regeneration process functions which
shall include:
i. The flow rate
of backwash or regeneration and its temperature dependency where applicable;
ii. The
duration of backwash or regeneration; and
iii. The
frequency of anticipated backwashes or regenerations;
2. The
approximate expected values, settings, or feed rates for pumps, gauges,
isolation valves, and controllers in the backwash mode; and
3. The backwash
disposal location and a copy of the backwash waste discharge registration
issued by the department;
e. Recommended short- and long-term maintenance
schedules for each piece of equipment;
f. A description of common operational problems and
proposed corrective operator responses;
g. A description of how the operator can maximize the
efficiency of the treatment process relative to:
1. Energy use;
2. Chemical use;
3. Maximizing the net treated water production volume;
and
4. Minimizing the volume of waste and by-products
produced; and
h. A blank copy of the compliance and oversight
operational form that is required by Env-Dw 503 to be
submitted to the department when a water system performs treatment.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.23)
Env-Dw 406.25 Water
Quality Monitoring Plan. The water quality monitoring plan
required by Env- Dw 406.22(f)(12) shall:
(a) Identify
recommended operational raw water test parameters and sampling frequencies; and
(b) Identify recommended operational finished
water test parameters and sampling frequencies in addition to compliance monitoring required in accordance with Env-Dw 701 through 719, as applicable.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.24)
Env-Dw 406.26 Distribution System.
(a) Subject to (c) below, the
system shall be designed to maintain a minimum pressure of 20 pounds per square
inch (psi) at ground level at all points in the distribution system under all
conditions of flow. The normal working pressure shall be approximately 60 to 80
psi and shall not be less than 35 psi.
(b) Subject to (c) below, when static pressure
exceeds 100 psi pressure reducing devices shall be installed on each individual
water service line at the meter or on the water main to maintain pressure at
less than 100 psi. Any bypass line around a water main pressure reducer shall
also have a pressure reducer. Where pressure reducers are installed below
ground, they shall be located in a vault, which shall have a gravity drain to
daylight with a rodent screen. The PWS owner shall maintain all pressure reducing
devices, whether on individual water service lines or on water mains, in proper
working order.
(c) Pressure shall be measured at ground level
including at service connections up to building entrances.
(d) Individual booster pumps shall not be allowed
for any individual residential service from the public water supply mains.
(e) The water distribution piping shall be so
valved as to allow isolation of major sections of the water distribution piping
system for repairs while still providing service to most of the water system.
(f) The spacing for inline isolation valves
installed on water mains shall not exceed every 800 feet. Isolation valves
shall be provided at all intersecting pipes. Isolation valves shall be located
at not more than 500-foot intervals in areas where the ground elevation is
below the flood hazard elevation as determined in accordance with Env-Dw 406.06(b) and in areas where water pipes are at a
reasonable risk of being damaged by erosion.
(g) Blow-offs or similar flushing devices shall
be installed to allow flushing of all water mains in the water distribution
piping system. Flushing devices shall be sized to provide flows which will give
a velocity of at least 3.0 feet per second in the water main being flushed.
Blow-offs and flushing devices shall not have drains, or the drains shall be
plugged, to prevent cross contamination.
(h) Dead-end piping shall be minimized. Dead-end
mains shall be equipped with a means to provide adequate flushing in accordance
with (g) above.
(i) Near the
temporary end of a water main, a gate valve shall be installed to allow future
piping extension without shutting down the system or jeopardizing the health of
existing consumers.
(j) Water distribution piping shall be bedded in
sand or other appropriate material in accordance with the applicable standard
of AWWA as listed in Env-Dw 402.
(k) Water distribution piping for year-round PWSs
shall be buried below the frost line.
(l) Subject to (n), below, a minimum horizontal
separation of 10 feet shall be maintained between water mains and gravity
sanitary or storm sewers, sewer force mains, sewer manholes, inlets, and other
structures, septic tanks, and subsurface treatment systems. The distance shall
be measured from outside edge to outside edge.
(m) Subject to (n) below, if a water main must
cross a gravity sanitary or storm sewer pipe or force main, the water main
shall cross above the sewer pipe with not less than 18 inches of clear
separation. At crossings, one full length of water pipe shall be located so
both joints will be as far from the sewer as possible. Special structural
support for the water and sewer pipes shall be provided as necessary.
(n) When conditions prevent the minimum
separation distances specified in (l) and (m) above, or when it is
impracticable to install water mains above sanitary or storm sewer pipes,
deviations from the requirements of (l) and (m) above shall only be allowed if
a specific waiver is granted by the department in accordance with Env-Dw 406.31. In addition to any other condition(s) imposed by
the department in granting the waiver, the following requirements shall apply be considered by the water system:
(1) The water
main shall be laid in a separate trench or on an undisturbed earth shelf
located on one side of the sewer and at an elevation so the bottom of the water
main is at least 18 inches above the top of the sewer pipe;
(2) The
sanitary or storm sewer pipe materials shall be pressure rated, and the
manholes, inlets, and other sewer structures shall be watertight and shall be
pressure or leak tested to demonstrate watertightness; and
(3) Where water
piping crosses under sanitary or storm sewer piping, a minimum of 18 inches
clearance shall be required.
(o) When pipes cross water bodies
15 feet or wider, pipes shall be buried at least 5 feet below the water body’s
bed, and isolation valves shall be installed on each side of the water body,
between the water body and the first service connection.
(p) Piping and valving material and installation
techniques shall conform with the appropriate AWWA specification, in accordance
with Env-Dw 402.
(q) Other utilities, including, but not limited
to natural gas, electric, telephone, steam, and cable television, shall not be
installed within 3 feet of water mains.
(r) All buried non-metallic piping shall be
backfilled with an effective metal tracing element located above the pipe
approximately 6 inches below the finished grade.
(s) Gate valves and service shut-offs shall be
equipped with cast iron gate box extensions. Gate valve boxes shall have cast
iron covers clearly marked by the word “water” or other appropriate water
supply marking and shall be installed flush with the finished grade.
(t) Rigid connections shall not be used to
construct or repair water distribution piping systems.
(u) The distribution system shall not include any
fixture which incorporates a stop and waste valve cross-connection, unless a
reduced pressure backflow device or air gap is used pursuant to Env-Dw 505.
(v) Any PWS that conducts a partial or full
replacement of a lead service line or galvanized service line requiring
replacement is subject to the requirements of 40 CFR 141 Subpart I.
(w) Handling and disposal of lead pipe,
galvanized pipe that might contain lead, or other lead components is subject to
Env-Hw 400, Env-Hw 500,
Env-Hw 800, and Env-Hw
1200.
(x) Where it is not practicable to bury a service
line below the frost line all the way to the building entrance, for example
under mobile homes, heat tape shall be
installed to prevent the service line from freezing. The length of above-ground
service pipe shall be minimized.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.25)
Env-Dw 406.27 Post-Construction
Procedures.
(a) Within 90 days after the water
system construction is complete, record drawings shall be submitted to the
department and to the operator showing precise horizontal dimensional
measurements, depth of bury, material type, and nominal size of all buried
water mains and piping, gate valves, blow-offs, hydrants, flushing devices,
service connections, and utility crossings.
(b) For purposes of this section,
“precise-dimensional measurements” means of sufficient accuracy to locate the
facility or appurtenance to within 1 foot accuracy, recorded to the nearest 0.5
foot.
(c) For NTNC water systems, prior to serving
water to the public, the owner shall submit a lead service line inventory and
lead service line replacement plan meeting the requirements of 40 CFR 141
Subpart I to the department for review and approval.
(d) The owner
shall maintain and update, as necessary, based on the best information
available to the owner, the PWS’s:
(1) Record
drawings and tie location records as required by Env-Dw
504.08; and
(2) Lead
service line inventory and replacement plan as required by 403.03(b).
(e) The owner shall
perform a leakage test of the buried water distribution piping system before
system use. The water distribution piping system shall be checked for leakage
in accordance with the appropriate AWWA standard specified in Env-Dw 402. Leakage shall not exceed the value given in the
appropriate AWWA standard specified in Env-Dw 402.
(f) For all non-community water systems, flushing
and chlorination of the water distribution piping system shall be completed
before use. Before the inspection of the water system by the department as
required by Env-Dw 405.28, the entire water system,
distribution pipes, water storage tanks, and pumps shall be flushed to remove
any dirt or other contaminants, and then chlorinated in accordance with the
appropriate AWWA standard, as specified in Env-Dw
402. After 24 hours, upon completion of the disinfection, the system shall then
be flushed again until chlorine residual is less than 0.1 milligrams per liter,
and a water sample shall be taken from
the end of the distribution system and analyzed for bacterial quality by a
laboratory accredited for such test by the New Hampshire environmental
laboratory accreditation program.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14
New. #14158, eff 12-25-24
Env-Dw 406.28 Notification of
Initiation of Water Service and Request for Inspection.
(a) Subject to (b)
below, upon completion of the construction of a non-community PWS and all
required testing, but no later than 10 working days preceding the start of
water service, the owner shall notify the department of the proposed date of
the start of water service and request an inspection, of the water system. The
PWS shall not initiate service until 10 days after all notifications are
provided in writing to the department.
(b) As part
of or prior to the notification required by (a) above, the owner shall submit
to the department:
(1) Written
verification of completion of construction, disinfection of all water system
components that will come into direct contact with potable water, and
completion of all required testing;
(2) The
operation and maintenance manual required by Env-Dw
406.24;
(3) The record
drawings required by Env-Dw 406.27(a); and
(4) The lead
service line inventory required by Env-Dw 406.27(c).
(c) The certified operator,
knowledgeable of the water system, shall be in attendance at the inspection by
the department.
(d) For existing PWSs, an inspection by the
department shall not be required for construction of water main replacement
extension, or both, including water service connections, but the owner shall
submit the information required in (b)(1)
and (3) above to the department.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14
New. #14158, eff 12-25-24
Env-Dw 406.29 Modifications and
Expansions.
(a) Any person
seeking to expand a non-community PWS shall submit the following to the
department:
(1) Historical
water use data for at least the past 2 years;
(2) The
proposed design flow calculated in accordance with Env-Dw
406.11; and
(3)
Documentation demonstrating the existing source(s) have the required
supply capacity as required by Env-Dw 406.12.
(b) Any person
seeking to modify or expand a PWS in accordance with Env-Dw
406.05 shall submit the following to the department:
(1) A written
request to amend the design approval;
(2) A
description of the necessary changes;
(3) An
explanation of why the changes are needed;
(4) Plan
sheets, including revisions to previously approved plans, and the following, if
applicable:
a. For new
well(s), the information in Env-Dw 406.13 through
406.16;
b. For storage
tank(s), the information in Env-Dw 406.20;
c. For pump
controls and auxiliary equipment, the information in Env-Dw
406.18;
d. For a
pumphouse or pump room, the information in Env-Dw
406.17;
e. For well
appurtenances and pumps, the information in Env-Dw
406.19;
f. For wiring
and control devices, the information in Env-Dw
406.21;
g. For water
treatment facilities, the information in Env-Dw
406.22, 406.23, and 406.25; and
h. For water
distribution systems, the information in Env-Dw
406.26;
(5) Revised
calculations, as applicable;
(6) If
infrastructure is decommissioned, photo documentation showing a minimum 12-inch
gap in the piping from the original well(s), storage tank(s), and any other
decommissioned infrastructure;
(7) If
connection to another PWS is proposed, documentation from the supplying owner
certifying that:
a. Adequate
quantities of water are available to serve the proposed PWS; and
b. With the
proposed PWS online, adequate system pressures and source capacity will be
maintained; and
(8) The design
fee as required by Env Dw-402.03.
(c) For
deepening or hydrofracturing of wells, the applicant shall submit:
(1) The well
capacity after hydrofracturing or deepening determined pursuant to Env-Dw 406.15; and
(2) The water
quality analysis results of the water from each well as specified in Env-Dw 406.16.
(d) Replacement in-kind does not
require department approval, except that replacement of a well shall comply
with the requirements of Env-Dw 406.13 through Env-Dw 406.16.
(e) The plans and specifications for
modifications to PWSs having a design flow greater than 20,000 gpd shall be
sealed by a professional civil or sanitary engineer licensed in the state of
New Hampshire.
(f) The department shall approve the application
to modify the non-community PWS if the design meets the criteria in this part.
Source. (See Revision Note at part heading for Env-Dw 405) #10612, eff 6-1-14
New. #14158, eff 12-25-24
Env-Dw 406.30 Expiration and
Extension of Design Approvals.
(a) Any final design approval for
a proposed non-community water system shall expire 4 years after issuance if
the pumphouse and 25% or more of the proposed water distribution piping system
have not been completed and the water system has not started operation.
(b) A new design review fee and appropriate
design revision shall be required for review and re-approval of lapsed designs.
(c) A new complete water quality test shall be
required for each source for the appropriate parameters listed in Env-Dw 702 through Env-Dw 706 for
re-approval of lapsed designs.
(d) To request
an extension to a non-community water system design approval, the owner shall
submit a written request for extension, including:
(1) Specific
reason(s) why the extension is being sought;
(2) The new
construction schedule;
(3)
Confirmation that no changes have been made to the original approved
design; and
(4) A new water
quality test for each source for the appropriate parameters listed in Env-Dw 406.16.
(e) After
reviewing an extension request, if the department finds that the previously
approved design will ensure that the project is consistent with all applicable
requirements in place at the time the extension request was received, the
department shall extend the approval for a reasonable amount of time, under the
circumstances, not to exceed 4 years.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.29)
Env-Dw 406.31 Waivers.
(a) Any applicant or
supplier of water who would be adversely impacted by the strict application of
a rule in this part and who wishes to request a waiver of the rule shall do so
in accordance with Env-Dw 202.
(b) Waivers shall not be granted for criteria
which pose a direct risk to public health, including but not limited to, proper
well construction, multiple wells where required, water quality standards, or
the integrity of water storage tank(s).
(c) A waiver
requests for a non-community water system’s SPA shall be submitted by the owner
as follows:
(1) All
requests for waivers shall be submitted as specified in Env-Dw
202 and shall be signed by the owner and the water system’s designer; and
(2) The request
shall include information on technically-important factors for a waiver of the
SPA such as historical water quality, if applicable, overburdened soil depth,
soil type, height and consistency of water table, direction of slope, and
potential contamination sources.
Source. (See Revision Note at part heading for Env-Dw 406) #10613, eff 6-1-14; ss by #14158, eff 12-25-24
(formerly Env-Dw 406.28)
Appendix A: State
Statutes and Federal /Regulations Implemented
|
Rule
Section(s) |
State
Statute(s) Implemented |
Federal
Requirement(s) Implemented |
|
Env-Dw
401.01-401.03 |
RSA 485:1, II(c) |
|
|
Env-Dw
401.04 |
RSA 485:3, I |
40 CFR 141.5 |
|
Env-Dw 401.05 |
RSA 485:1, II(d) |
|
|
Env-Dw
402 |
RSA 485:41, III |
|
|
Env-Dw
402.01 |
RSA 485:1, II(c) |
40 CFR 142 Subpart B |
|
Env-Dw
402.02 |
RSA 485:8, III & IV |
|
|
Env-Dw
402.03 |
RSA 485:3, I(c); RSA 485:8 |
40 CFR 142 Subpart B |
|
Env-Dw
402.04 |
RSA 485:3, XII |
42 USC 300g-9 |
|
Env-Dw
402.05 |
RSA 485:8, I & II |
42 USC 300f(4)(A); 40 CFR
142 Subpart B |
|
Env-Dw
402.06 |
RSA 485:3, III; RSA 485:42 |
40 CFR 142 Subpart B |
|
Env-Dw
403 |
RSA 485:3, VIII |
40 CFR 143.12; 40 CFR 141
Subpart I |
|
Env-Dw 404.01 – 404.11 |
RSA 485:3, I; RSA 485:8 |
40 CFR 141 Subpart I |
|
Env-Dw 405.01 - 405.33 |
RSA 485:1, II(c); 485:8 |
40 CFR 141 Subpart I |
|
Env-Dw 406.01 – 406.31 |
RSA 485:1, II(c); RSA 485:8 |
40 CFR 141 Subpart I |
Appendix B: Incorporation By Reference Information
|
Rule Section(s) |
Title |
Dated |
Obtain at: |
|
Env-Dw
402.06; Table 402-1 |
American Water Works
Association Standards A100 through F120 |
Various |
The NH Department of
Environmental Services office Or https://store.awwa.org/standards?custitem_facet_standards_field=Current-Standards |
|
Env-Dw
403.01 |
2024 |
American National
Standards Institute https://webstore.ansi.org/standards/nsf/nsfansi602021600 |
|
|
Env-Dw
403.01 |
“Drinking Water System Components – Health Effects”,
(61) ANSI document Identification number NSF/ANSI 61-2023, American National
Standards Institute, 2023. |
2023 |
American National
Standards Institute https://webstore.ansi.org/standards/nsf/nsfansi612021600 |
|
Env-Dw
404.04(a) |
“Recommended Standards for
Water Works, Policies for the Review and Approval of Plans and Specifications
for Public Water Supplies”, A Report of the Water Supply Committee of the
Great Lakes – Upper Mississippi River Board of State and Provincial Public Health
and Environmental Managers, 2022. |
2022 |
NH Department of
Environmental Services office or https://www.health.state.mn.us/c ommunities/environment/water/t enstates/standards.html |
|
Env-Dw
404.05(p); Env-Dw 405.06(c); Env-Dw 406.06(c) |
“New Hampshire Coastal
Flood Risk Summary – Part I: Science and Part II: Guidance for Using
Scientific Projections" prepared for the New Hampshire Coastal Flood
Risk Science and Technical Advisory Panel, 2019. |
2019 |
University of New
Hampshire https://scholars.unh.edu/ersc/210 and https://scholars.unh.edu/ersc/211 |
|
Env-Dw
405.17(f), Env-Dw 405.20(j), and 406.19(j) |
National Electrical
Manufacturers Association Standard ANSI/NEMA MG 1-2021 “Motors and
Generators”, 2022. |
June 29, 2022 |
National Electrical
Manufacturers Association (NEMA) |
|
Env-Dw
405.21(g) and Env-Dw 406.20(h) |
American Society of
Mechanical Engineers (ASME) “Boiler and Pressure Vessel Code Section
VIII-Rules for Construction of Pressure Vessels”, Division 1
BPVC.VIII.1-2023, 2023. |
2023 |
American Society of
Mechanical Engineers (ASME) |